![MantelMount MM855 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/mantelmount/mm855/mm855_installation-instructions-manual_1723733008.webp)
FIG. C
(view facing the wall)
FIG. B
(view from inside the wall)
FIG. A
(view from inside the wall)
This unique MantelMount feature will allow the mount to lower
to the the Memory 1 position whenever the TV is turned on,
and return home when the TV is turned off. The mount will do
this automatically without needing to use the Remote Control.
If the TV is plugged into the socket located onboard the MM800
instead of a wall outlet, MantelMount can monitor the power to
the TV and determine when it is turned on or off.
If this feature is not desired, simply plug the TV into a wall
outlet and operate the MM800 with the Remote Control.
PAGE 8
MantelMount MM8
Auto Lowering Power Sensor (ALPS):
opening
OPTIONAL:
MM800 has a rear access hole that accepts threaded fittings for
standard 1/2” aluminum conduit. A licensed electrician can
hard wire the mount by splicing into the power cord.
Contact MantelMount for more information.
Hard Wire Conduit Access:
OPTIONAL:
MM800 includes brackets that make it easier to install horizontal 2x4 bracing inside the
wall. This is because all the attachment holes in the brackets can be reached for drilling
and screwing through the opening that is cut for the Lift Housing {30}, see FIG. A.
Notes: If the bracket is near the cutout opening, make sure to orient the attaching
hardware away from the opening so they do not interfere with the Housing. This
hardware is attached before the braces are installed into the wall, see FIG. B.
When cutting a center stud, measure 1.5” above and below the template mark before
the opening is cut out. Plunge cut through the stud at both locations and attach the cut
ends to the cross braces when they are installed, see FIG. C.
Adapter Brackets for 2x4 bracing:
OPTIONAL:
ALPS Socket for TV
1.5”
1.5”