Operator’s Manual
Self-Propelled Scissor Lift
Version 1
35
8
Error Codes (Only for Type B Platform Controller)
If an error occurs on a machine equipped with a type B platform controller, an error code will appear
on the display of the platform controller.
More information about these error codes, their possible cause and solutions can be found in the table
below.
Error Code
Problem
Possible Cause
Solutions
01
Electronic Control
Module (ECM) error
No progress in ERPOM
Replace the Electronic Control
Module (ECM)
02
ECM/Platform
controller
communication error
Cable or platform
controller failure
Find the fault of the cable and/or
platform controller
03
Platform DIP switch
error
DIP switch setting is not
correct
Change the DIP switch setting
12
Up/Down switch
error
Up/Down switch failure
Check the Up/Down switch on the
ground control panel
18
Pothole guard error
Pothole guard switch
failure or pothole guard
coupling blocked
Check the pothole guard switch
and/or remove obstacle
19
Limit switch error
Limit switch failure or
limit switch wire broken
Check the limit switch and/or check
limit switch wire
42
Turning left switch
error
Turning left switch
failure
Check the turning left switch on the
control handle
43
Turning right switch
error
Turning right switch
failure
Check the turning right switch on
the control handle
46
Function enable
switch error
Function enable switch
failure
Check the function enable switch
on the control handle
47
Platform control
handle error
Control handle not in
median
Recalibrate control handle
(potentiometer)
52
Forward valve coil
error
Coil failure or coil
disconnected
Check forward valve coil and wiring
53
Backward valve coil
error
Coil failure or coil
disconnected
Check backward valve coil and
wiring
54
Raising valve coil
error
Coil failure or coil
disconnected
Check raising valve coil and wiring
55
Lowering valve coil
error
Coil failure or coil
disconnected
Check lowering valve coil and
wiring
56
Right turn valve coil
error
Coil failure or coil
disconnected
Check right turn valve coil and
wiring
57
Left turn valve coil
error
Coil failure or coil
disconnected
Check left turn valve coil and wiring