AVS 24v S-SERIES INSTALLATION MANUAL - GEN 2 VER 4
20
Programming functions Register 2
continued
Vehicle set up: Open a door, close bonnet & boot, arm & disarm alarm then turn ignition
on, off & on.
Feature:
Indicator flash on alarm trigger
Press the
button
this many times:
6
Factory setting:
ON
Description:
When turned OFF, this feature prevents the indicators from flashing when the system
is triggered. The indicators will still flash on arm and disarm as well as in panic mode.
Feature:
Extended lock pulse
For central closure
Press the
button
this many times:
7
Factory setting:
OFF
Description:
When this feature is turned ON, the lock output becomes a 15 second pulse instead of
0.5 seconds. For use with vehicles with vacuum central locking or those with a central
closure wire (some BMW, Mercedes) i.e. doors lock, electric windows wind up, sunroof
closes automatically.
Feature:
Extended unlock pulse
Press the
button
this many times:
8
Factory setting:
OFF
Description:
When this feature is turned ON, the unlock output becomes a 15-second negative pulse
instead of 0.5 seconds. This feature is for use with vehicles with vacuum central locking.
Feature:
Anti Hijack – Mode 1
Press the
button
this many times:
9
Factory setting:
OFF
Description:
When this feature is turned ON, the unit will enter anti hijack mode 1 following the
opening of a door while the ignition is on. Upon entering anti hijack mode, the unit will
begin waiting for a disable notification by pressing the momentary switch. The LED will
flash each second of the countdown to notify the user it is in anti hijack mode (can be
turned off via
Register 2, Feature 14
).
If this is not performed within 30 seconds of a door being opened, the siren will emit
four warning chirps and the indicators will flash. 30 seconds later if the switch has still
not been pressed, the unit will trigger the anti hijack mode. Immobiliser 3 (fuel pump)
will open, immobilising the vehicle and will stay open until the ignition is turned off
then on and the momentary switch is pressed or pin code is entered. The alarm will also
activate for five minutes after the anti hijack trigger (can be turned off via
Register 2,
Feature 11
).