Electrical Connection: Standard Model. See Diagram 1.Timer model, Diagram 2.

 

 
Remove the internal cover by removing the 2 small caps and retaining Philips screws to access the 
terminal connections. The fan can either be operated from a separate pullcord switch fitted to the ceiling 
of the room or can be connected to the light switch so that the fan will start when the light is switched on. 
The fan should not be accessible to a person using either the shower or the bath.

 
Timer Adjustment 

 

 
The Timer fan will run approximately one minute after it has been switched off. This time delay can be 
increased by firstly switching off the power to the fan. Remove the cover and the timer cover as detailed 
in diagram 2A. Insert a small screwdriver into the slot, marked        in Diagram 2A, and turn clockwise to 
reduce the time and anti-clockwise to increase the time. 

Only adjust with power switched off

. the timer 

will run for is 30 seconds and the maximum is about 20 minutes.  

NB Timer delay is adjustable as indicated on the timer strip cover. 

Diagram 2

Diagram 2A

1

MIN

MAX

10

15

20

30

TIMER MINUTES

FIXING HOLES

CABLE ENTRY

FIXING HOLES

CABLE
GRIP

MOTOR WIRE

MIN

MAX

10

30

15

20

+

DETAILED VIEW

Only adjust with power switched off

TIMER MIINUTES

PCB BOARD

COVER

POWER

CABLE

ENTRY

1

3 AMP

DOUBLE POLE

FUSED SPUR

_
NEUTRAL

+

LIVE

PULLCORD

SWITCH / LIGHT SWITCH

MIN

MAX

10

30

15

20

+

        Switched Live

                  Permanent Live

                Neutral

1

Diagram 2

Содержание LP 100

Страница 1: ...hould be arranged to slope slightly away from the fan Ducts passing through cold voids must be suitably insulated 4 Do not install the unit within a shower cubicle or anywhere else where there is a risk of being sprayed with water Please see our range of showerfans for these installations 5 If the fan is installed in a room containing a fuel burning appliance the installer must ensure that the air...

Страница 2: ...on as marked Allow an extra 230mm 9 protruding to facilitate connection SECURE CORD GRIP 9mm 6mm 9mm 9 m m 2 3 POWER SUPPLY PO W ER SU PP LY Terminal 1 live supply in Terminal 2 neutral supply in TRIM CABLE TERMINAL BLOCK POWER CABLE ENTRY MOTOR WIRE POWER CABLE COVER SCREW FIXING HOLES 3 AMP DOUBLE POLE FUSED SPUR _ NEUTRAL LIVE REMOTE PULLCORD SWITCH LIGHT SWITCH HOLES FIXING HOLES Fixing clip C...

Страница 3: ...e increased by firstly switching off the power to the fan Remove the cover and the timer cover as detailed in diagram 2A Insert a small screwdriver into the slot marked in Diagram 2A and turn clockwise to reduce the time and anti clockwise to increase the time Only adjust with power switched off the timer will run for is 30 seconds and the maximum is about 20 minutes NB Timer delay is adjustable a...

Страница 4: ...duced to a normal level about 65 Connect to electrical supply as shown in diagram 3 Neutral Switched Live Spare Permanent Live PCB Board Cover Motor Wire Humidity operated time delay control Diagram 3 Time delays humidity over risde operation Terminal 1 1 Neutral Terminal 2 2 Switch live Supply Terminal 3 3 Spare Terminal 4 4 Permanent Supply 077286 LP100 LP120 T Max 40 C Rated 220 240V 50Hz 20W q...

Отзывы: