Electrical Connection: Standard Model. See Diagram 1.Timer model, Diagram 2.
Remove the internal cover by removing the 2 small caps and retaining Philips screws to access the
terminal connections. The fan can either be operated from a separate pullcord switch fitted to the ceiling
of the room or can be connected to the light switch so that the fan will start when the light is switched on.
The fan should not be accessible to a person using either the shower or the bath.
Timer Adjustment
The Timer fan will run approximately one minute after it has been switched off. This time delay can be
increased by firstly switching off the power to the fan. Remove the cover and the timer cover as detailed
in diagram 2A. Insert a small screwdriver into the slot, marked in Diagram 2A, and turn clockwise to
reduce the time and anti-clockwise to increase the time.
Only adjust with power switched off
. the timer
will run for is 30 seconds and the maximum is about 20 minutes.
NB Timer delay is adjustable as indicated on the timer strip cover.
Diagram 2
Diagram 2A
1
MIN
MAX
10
15
20
30
TIMER MINUTES
FIXING HOLES
CABLE ENTRY
FIXING HOLES
CABLE
GRIP
MOTOR WIRE
MIN
MAX
10
30
15
20
–
+
DETAILED VIEW
Only adjust with power switched off
TIMER MIINUTES
PCB BOARD
COVER
POWER
CABLE
ENTRY
1
3 AMP
DOUBLE POLE
FUSED SPUR
_
NEUTRAL
+
LIVE
PULLCORD
SWITCH / LIGHT SWITCH
MIN
MAX
10
30
15
20
–
+
Switched Live
Permanent Live
Neutral
1
Diagram 2