Part Number 80-1479-3 7/10
39
Step 15
Reapply power to the ice machine and place
the toggle switch in the CLEAN position.
Step 16
Wait until the water trough refills and water
flows over the evaporator (approximately 3 minutes).
Add the proper amount of Manitowoc Ice Machine
Sanitizer to the water trough by pouring between the
water curtain/splash shields and evaporator..
Step 17
Move the toggle switch to the ICE position
and replace the front panel. The ice machine will
automatically start ice making after the sanitize cycle
is complete (approximately 35 minutes, S3300 - 80
minutes).
Model
Amount of Sanitizer
S300/S320/S420
3 ounces (90 ml)
S450/S500/S600/S850/
S1000/S1200
3 ounces (90 ml)
S1400/S1600/S1800
6 ounces (180 ml)
S3300
25 ounces (740 ml)
Содержание S300
Страница 2: ......
Страница 20: ...20 Part Number 80 1479 3 7 10 This Page Intentionally Left Blank ...
Страница 36: ...36 Part Number 80 1479 3 7 10 A B C D E ...
Страница 45: ...Part Number 80 1479 3 7 10 45 A B C D E F G ...
Страница 48: ...48 Part Number 80 1479 3 7 10 A A B C D E F G H I ...
Страница 79: ...Part Number 80 1479 3 7 10 79 This Page Intentionally Left Blank ...
Страница 80: ...80 Part Number 80 1479 3 7 10 This Page Intentionally Left Blank ...
Страница 133: ...Part Number 80 1479 3 7 10 133 This Page Intentionally Left Blank ...
Страница 134: ...134 Part Number 80 1479 3 7 10 This Page Intentionally Left Blank ...
Страница 175: ...Part Number 80 1479 3 7 10 175 REMOTE RECOVERY EVACUATION CONNECTIONS ...
Страница 184: ...184 Part Number 80 1479 3 7 10 SV1406 USING PINCH OFF TOOL ...
Страница 189: ...Part Number 80 1479 3 7 10 189 This Page Intentionally Left Blank ...
Страница 190: ...190 Part Number 80 1479 3 7 10 This Page Intentionally Left Blank ...
Страница 296: ...296 Part Number 80 1479 3 7 10 This Page Intentionally Left Blank ...
Страница 297: ...Part Number 80 1479 3 7 10 297 This Page Intentionally Left Blank ...
Страница 298: ...298 Part Number 80 1479 3 7 10 ...
Страница 299: ......