![Manitowoc NBT60XL Скачать руководство пользователя страница 173](http://html.mh-extra.com/html/manitowoc/nbt60xl/nbt60xl_operators-manual_701284173.webp)
NATIONAL CRANE
Published 11-01-2020 Control # 710-00
7-19
NBT60XL OPERATOR MANUAL
RATED CAPACITY LIMITER
7
To enter the calibration password:
1.
Access the Sensor Calibration Menu.
The Password screen appears.
2.
Enter the following. Use the directional arrow key,
highlight the number, then press
to populate the
field.
1, 2, 3, 3, 1
3.
Select the sensor you want to calibrate.
4.
After all numbers are entered, press the green
Select function key to submit the password.
Setting System Date and Time
Use the following procedure to set the RCL system Date and
Time. Table 7-11 shows the functional keys available in the
Time Set screen.
1.
In the System Configuration menu, select the Time Set
icon
.
The Time Set screen appears.
2.
Do the following to update the field(s):
•
Use the cycle button
as needed to tab through
the fields available to update.
•
Use the Increment/decrement button
as needed
to increase or decrease the value in the highlighted field.
3.
Press the Select button
to save changes.
CALIBRATING RCL SENSORS
The RCL sensors are located throughout the crane and are
used to monitor the lifting parameters set by the crane
operator.
When a sensor requires calibration, its icon appears with a
RED background in the RCL. Table 7-12 shows the Sensor
Calibration warning icons. The sensors are calibrated at the
factory before the crane is delivered, but need to be
calibrated in the following circumstances:
•
The sensor readings are inaccurate (individual sensor
only must be calibrated)
•
The sensor or component being measured is replaced,
adjusted, removed, or reinstalled (individual sensor only
must be calibrated)
•
The software has been updated (all sensors must be
calibrated)
•
The RCL display is replaced (all sensors must be
calibrated)
For more information about RCL calibration and related
maintenance procedures, see the
Service Manual
.
Table 7-11 Time Set Functional Keys
Icon
Description
Use this button to set changes to a field.
Use this button to cycle (tab) through the
fields that can be changed.
Use this button to increase and decrease the
value in the selected field.
Use this button to return to the System
Configuration screen without saving
changes.
Use this button to return to the main menu.
9683
Fo
r
Reference
Only
Содержание NBT60XL
Страница 1: ...Operator Manual National Crane NBT60XL 9731 10255 F o r R e f e r e n c e O n l y ...
Страница 4: ...THIS PAGE BLANK F o r R e f e r e n c e O n l y ...
Страница 126: ...SET UP OPERATOR MANUAL NBT60XL 4 30 Published 11 01 2020 Control 710 00 THIS PAGE BLANK F o r R e f e r e n c e O n l y ...
Страница 183: ...F o r R e f e r e n c e O n l y ...
Страница 184: ...F o r R e f e r e n c e O n l y ...