12
Part Number 000008463 Rev 02 3/16
Installation
Section 2
6. Route line voltage wires (black and white) through line
voltage Heyco fitting and attach to L1 and L2 contactor
terminals.
Route Through Line Voltage Heyco
and
Attach to Contactor Terminals
22" Models - Connect Line Voltage to bottom Terminals of L1 & L2
QuietQube Model Line Voltage Wiring
QuietQube models do not have a contactor. Disconnect L1
and N wires and install L1 and N of wiring adapter to the
incoming power supply wires. Connect removed wires and
LuminIce® wires to adapter.
7. Route low voltage wiring (black and yellow wires) to
the LuminIce®. Install wire clip and route wires close to
evaporator bulkhead to assure harness is away from
any moving parts, then snap wire harness connectors
together.
8. Refer to picture and install LuminIce® hoses.
Install wire clip and route wires
along evaporator bulkhead.
9. Install the notched evaporator dust cover from kit and
test run the ice machine and LuminIce®. The LuminIce®
is energized whenever power is applied to the ice
machine.
Wires Removed From L1 & N
Connect Wires To L1 & N
Luminice® Power