10
Part Number 000008463 Rev 02 3/16
Installation
Section 2
6. Route transformer low voltage wiring (black and
yellow wires) to the LuminIce®. Snap the wire harness
connectors together. Bundle and secure any excess low
voltage wires near the transformer.
7. Cut the LuminIce® hose to length and attach:
NOTE: The upper bulkhead adapter connects to the upper
connector on the LuminIce® and the lower bulkhead
adapter connects to the lower LuminIce® connector.
• Insert tubing onto the lower bulkhead adapter and
dry fit to establish length, then cut to fit. Attach to
LuminIce® and secure with snap clamp.
• Insert tubing onto the upper bulkhead adapter and
dry fit to establish length, then cut to fit. Attach to
LuminIce® and secure with snap clamp.
• Reinstall the evaporator dust cover.
8. Test run:
• Install all panels except the front panel.
• Restore power - The LuminIce® is energized
whenever power is applied to the ice machine. A
noticeable draft and a discharge of photoplasma
will be emitted from the upper hose adapter during
operation.
LuminIce® Installation 22" & 30" Wide Single
Evaporator Models
n
Warning
Disconnect power to ice machine at the electrical
disconnect. Pressing the power button does not
disconnect line voltage.
1. Disconnect all power to the ice machine at the
electrical disconnect.
2. To allow access for LuminIce® tubing, the evaporator
dust cover and plastic caps in the evaporator and
compressor compartment bulkhead wall must be
removed and discarded.
Remove Plastic Caps From Bulkhead In The
Evaporator And Compressor Compartment