Procedure M - Counterweight Removal Valve
1.
Install pressure check diagnostic quick disconnect with
gauge onto test nipple at main directional control valve
load sense relief test port Figure 2-7.
2.
With engine at full rpm, retract counterweight cylinder
and set relief valve on counterweight valve Figure 2-16
to 1750 psi ±50 (12.1 MPa ±.4); turn in to raise or out to
lower pressure.
3.
Remove pressure gauge from main directional valve.