2 - 21
32 - S
OUND ALARM HORN
- This sound alarm 19 horn located on the turret, is activated when we press
on the button 32.
33 - A
LARM BUZZER
- This alarm buzzer is activated when the machine are in the two
followings cases:
-
Case 1 ;
INTERMITTENCE
:
When the authorized slope limit is
reached, all the movements are stopped, with the exception of
the lowering of the arms and the telescope. It can therefore be
returned to an acceptable level of tilt.
-
Case 2 ;
CONTINUOUS
:
When the access platform is in
overload, all the movements are stopped, with the exception
of the lowering of the telescope and the inferior arms.
Reminder: see page 2-5