The following warnings are posted throughout the motorhome to provide information on LP
Gas safety. They have been installed not only because of the requirement to do so, but also
as a constant reminder to occupants of the motorhome to exercise proper caution when using
or being around LP Gas appliances and equipment. We are listing them here so you may
study them and make sure that you and your family understand and follow them.
WARNING: It is not safe to use cooking appliances for comfort heating.
WARNING: Cooking appliances need fresh air for safe operation. Before operation:
1. Open overhead vent or turn the exhaust fan on
2. Open windows
This warning label has been located in the cooking area to remind you to provide an
adequate supply of fresh air for combustion. Unlike homes, the amount of oxygen supply is
limited due to the size of the motorhome, and proper ventilation when using the cooking
appliances will avoid dangers of asphyxiation.
Over-filling the LP Gas container can result in uncontrolled gas flow which can cause fire or
explosion. A properly filled container will contain approximately 80% of its volume as liquid
LP Gas. An 80% automatic shut-off valve is installed on the LP Gas tank which will
automatically prevent further filling when the gas volume has reached 80% of tank capacity.
CAUTION: This tank is equipped with an automatic valve designed to close at
80% liquid full. Always open 20% fixed liquid level bleeder gauge while filling.
Stop filling if liquid appears before valve shuts off.
WARNING: All LP Gas is contained under pressure. Due to the dangerous
potential of any compressed gas, it is mandatory that the following
requirements for the use of this tank be followed: Tanks are to be installed,
fueled and maintained in accordance with the state and local codes, rules,
regulations or laws and in accordance with the NFPA Pamphlet 58, division IV.
WARNING: Only personnel trained in the handling of LP Gas may fill, test or
repair the LP Gas system.
1-3
IDENTIFICATION & SAFETY
2005 PRESIDIO
SAFETY REGULATIONS FOR LP GAS SYSTEMS & APPLIANCES
Содержание 2006 Presidio
Страница 1: ...2005 PRESIDIO 08 2005 Revision 1...
Страница 2: ...2005 PRESIDIO...
Страница 4: ...2005 PRESIDIO...
Страница 6: ...2005 PRESIDIO...
Страница 7: ...2005 PRESIDIO...
Страница 8: ...2005 PRESIDIO...
Страница 12: ...TABLE OF CONTENTS 2005 PRESIDIO...
Страница 22: ...X 2005 PRESIDIO INTRODUCTION...
Страница 36: ...1 14 IDENTIFICATION SAFETY 2005 PRESIDIO...
Страница 62: ...3 12 DASH CONTROLS INSTRUMENT PANELS 2005 PRESIDIO...
Страница 96: ...7 14 ELECTRICAL SYSTEMS 2005 PRESIDIO...
Страница 116: ...9 10 LP GAS SYSTEMS 2005 PRESIDIO...
Страница 130: ...10 14 CARE MAINTENANCE 2005 PRESIDIO...