18.2.11 Time/Date
Transmission repetition rate:
1000 ms
Data length:
8 bytes
Identifier:
0x18 FE E6 27
Byte 1:
Seconds (MAN internal UTC)
0.25 s per bit
0 s offset
Range: 0 ... 59.75 s
SAEJ1939-71: SPN 959
Byte 2:
Minutes (MAN internal UTC)
1 min per bit
0 min offset
Range: 0 ... 59 min
SAEJ1939-71: SPN 960
Byte 3:
Hours (MAN internal UTC)
1 h per bit
0 h offset
Range: 0 ... 23 h
SAEJ1939-71: SPN 961
Byte 4:
Month (MAN internal UTC)
1 month/bit
0 month offset
Range: 0 ... 12 month
SAEJ1939-71: SPN 963
Byte 5:
Day (MAN internal UTC)
0.25 day per bit
0 day offset
Range: 0 ... 31.75 day
SAEJ1939-71: SPN 962
Byte 6:
Year (MAN internal UTC)
1 year per bit
+1985 year offset
Range: 1985 ... 2235 year
SAEJ1939-71: SPN 964
Byte 7:
Local minute Offset
1 min per bit
-125 min offset
Range: -125 ... 125 min
SAEJ1939-71: SPN 1601
Byte 8:
Local hour Offset
1 h per bit
-125 h offset
Range: -125 ... 125 h
SAEJ1939-71: SPN 1602