Faults
MAN marine diesel engines D2868 LE4.. / D2862 LE4..
96
Carefully read through the Operating Instructions before starting any work!
This particularly applies to the General Safety Instructions section
and the safety instructions in the various chapters.
MMDS CLC 6.5 colour display on the control stand
If a value reaches a critical level, a warning mes
sage or an alarm is tripped and shown on the dis
play, depending on importance. If the value ex
ceeds certain plausible limits, a sensor fault is
displayed. An integrated buzzer emits a warning
sound each time a new alarm message is issued.
This sound can be stopped at the push of a button.
A separate alarm table lists all pending alarms with
detailed information. Examples of alarms are
shown on the illustration opposite.
The system makes a distinction between:
S
Alarm, e.g. EDC combined fault, red, 3100 SPN
S
Warning, e.g. SFFR combined fault, orange,
4022 SPN
S
Sensor fault, e.g. gearbox oil pressure, yellow
The "SPN numbers", see "Value" column in table
opposite, are used by MAN Service to identify the
fault.