Repairing coolant pump
49
Installation note for mechanical seal
Fit the mechanical seal “wet”, i.e. when fitting, coat holding sleeve
Ã
and coolant pump shaft
À
with a mix-
ture of 50% water and 50% cleaning spirit or 40% to 50% antifreeze as per MAN 324 and water.
Other anti-skid agents must not be used.
Because the seal on collar
Á
is coated with sealing paint, no sealing paint needs to be applied if the locat-
ing bore in the coolant pump housing is in perfect condition.
If the bore shows even the slightest scoring or other minor damage, a sealing bead of Dirko-Transparent,
must be applied to collar
Á
.
Fit the seal with a plastic transportation cap
Â
onto shaft
À
and use installation tool to press it in until the
tool contacts the housing. Remove the plastic cap.
1
2
3
4
5
Note:
Tests have shown that most cases of damage to the coolant pump can be attributed to the use of
unsuitable coolants.
Only
those anticorrosion and antifreeze agents expressly approved by MAN Nutzfahrzeuge AG
as per the MAN 324 standard (see brochure “Fuels, Lubricants ...”) will guarantee fault-free oper-
ation.
Содержание D 2840 LE 301
Страница 1: ......
Страница 2: ......
Страница 16: ...Notes 14...
Страница 20: ...Engine views 18 Engine views D 2842 LE 301 9 10 11 12 9 8 6 5 4 3 2 1 13 14 15 16 17 18 6 7 8...
Страница 150: ...Notes 148...
Страница 151: ...149 Service Data...
Страница 179: ...177 Special tools...
Страница 180: ...Special tools 178 2 3 4 5 6 7 8 1 6 1 6 2 6 3 9 1 9 2 9 3 9...
Страница 182: ...Special tools 180 10 11 16 14 14 1 12 13 18 18 1 12 1 12 2 15 5 15 4 15 1 15 1 15 2 15 3 15 3 15 6 15 7 15 17...
Страница 184: ...Special tools 182 21 22 25 25 2 24 25 1 26 27 1 27 2 27 20 1 19 2 19 1 20 2 19 20 28 23...
Страница 186: ...Special tools 184 30 29 32 31 33...
Страница 189: ...Special tools 187 2843 Pressing mandrel for cap dia 50 1 mm Pressing mandrel for cap dia 62 1 mm...
Страница 193: ......
Страница 194: ......