background image

 

OPERATING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING:  If you do not follow these instructions exactly, a fi re or explosion may result 
 

  causing property damage, personal injury or loss of life.

A. Follow these instructions exactly.  This appliance has a pilot which must be lighted by hand.

B. BEFORE LIGHTING smell all around the appliance area for gas.  Be sure to smell next to the 

fl oor because some gas is heavier than air and will settle on the fl oor.

  WHAT TO DO IF YOU SMELL GAS

    Do not try to light any appliance.

    Do not touch any electric switch; do not use any  phone in your building.

  Immediately call your gas supplier from a neighbor's phone.  Follow the gas supplier's  

 

instructions.  If you cannot reach your gas supplier, call the fi re department.

C. Use only your hand to push in or turn the gas control knob.  Never use tools.  If the knob will 

not push in or turn by hand, don't try to repair it, call a qualifi ed service technician.  Force or 

attempted repair may result in a fi re or explosion.

D. Do  not use this appliance if any part has been under water.  Immediately call a qualifi ed service 

technician to inspect the appliance and to replace any part of the control system and any gas 

control which has been under water.

LIGHTING INSTRUCTIONS

1. STOP!  Read the safety information above on this label.

2. Push in the control knob slightly and turn clockwise              to "OFF".

NOTE:  Knob cannot be turned from "PILOT" to "OFF" unless knob is pushed in slightly.  Do not 

force.

3. Wait fi ve (5) minutes to clear out any gas.  If you smell gas, STOP!  Follow "B" in the safety 

information above on this label.  If you do not smell gas, go to the next step.

4. Turn knob on gas control counterclockwise 

      to "PILOT."

5. Push in control knob all the way and hold in.  Immediately light the pilot by pushing in the red 

lighter button. Continue to push the red lighter button until the pilot is lit.  Continue to hold 

the knob in for about one (1) minute after the pilot is lit.  Release the knob and it will pop back 

up.  If the knob does not pop up, turn off the gas shut off valve and call a service technician.  

Pilot should remain lit.  If it goes out, repeat steps 3 through 6.

6. Turn gas control knob counterclockwise     

 to "ON."

To Turn Gas Off

1. Push in gas control knob slightly and turn clockwise     

   to "OFF."  Do not force.

FD2/FD3 Page - 9

Pilot Assembly

CONTROL VALVE

el.

  

    

    

  

  

 

 

THERMOPILE
THERMOSTAT

THERMOPILE

THERMOSTAT

PILOT GAS TUBE

PILOT ADJ. SCREW

MANIFOLD PRESSURE TAP

INLET PRESSURE TAP

 

  

  

ON/OFF GAS 
CONTROL KNOB

GF2/3 5/1/15

Содержание Fire Drum GF-2

Страница 1: ...ately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the re department FOR YOUR SAFETY Do not store or use gasolineoro...

Страница 2: ...ture and draperies Unpack all parts from cartons carefully inspecting all parts If any parts are damaged or miss ing contact shipper or dealer immediately Do not install this appliance using damaged p...

Страница 3: ...ion of the appliance the hot ue gases reach the damper causing the damper plate to thereby open the vent passage within a short period of time Installation of vent dampers can increase the potential f...

Страница 4: ...ls out of the room and away from hot surfaces CLEARANCES Make sure that minimum clearances to combustible materials are maintained during installation including adequate space for the proper operation...

Страница 5: ...that wall clearances are correct prior to proceeding 4 Lift the control cover Using a 1 2 x 8 nipple extend the gas supply line to the front of the unit 5 Attach gas supply shut off valve part GF 1A t...

Страница 6: ...se Assembly GF3 Hood GF2 GF3 Page 6 Installation Instructions Continued UNIT ASSEMBLY GF2 A Place the body section into the base Align the opening with the control cover B Place the hood over the body...

Страница 7: ...ructions continued Attach the slip connector pipe to the support box Insert the slip connector pipe into the support box and twist to lock into place Slip the middle section over the slip section only...

Страница 8: ...Spread glowing embers evenly over the vermiculite After lighting the unit spread the embers to acheive an even coal effect 3 Place re logs as shown using alignment knobs on the logs 4 Light the pilot...

Страница 9: ...to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS 1 STOP Read the safety information above on this label 2 Push in the control knob slight...

Страница 10: ...ion air is not obstructed 4 If you are unsure how to perform these maintenance procedures have a quali ed eld ser vice person check the unit at least annually NOTE During the rst few res the odor of p...

Страница 11: ...10 MV 10 Pilot Assembly Robert Shaw PG9 11 MV 11 Piezo Lighter Electrode 12 MV 12 Pilot Hood 13 MV 13 Thermopile Robert Shaw 6 13 12 11 10 9 8 7 5 3 2 1 The pilot ame adjustment is labeled on the top...

Страница 12: ...NATURAL GAS 3 5 WC MAX 1 2 PSI FOR MILIVOLT SYSTEM ONLY LP PROPANE CONVERSION KIT 10 WC TH TP TP TH RED WHITE BLACK HIGH LIMIT SWITCH OPTIONAL WALL SWITCH THERMOSTAT OR REMOTE Page 12 CUT IF SWITCH US...

Страница 13: ...p Slip Pipe Starter Pipe Damper Gas Supply Line Flex Connector Gas Control Valve Piezo Lighter Adjustable Air Shutter Figure F Support Box Pilot Flame 12 3 4 12 3 4 Frame In 13 x 13 GF2 3 5 1 15 Front...

Страница 14: ...s ne pouvez pas joindre votre fournis seur de gaz appeler le service d incendie POUR VOTRE S CURIT Nepasstockerouutiliser essence ou autres vapeurs in ammables et des liquides dans le proximit de cet...

Страница 15: ...chand imm diatement Ne pas installer cet appareil en utilisant les pi ces endommag es ALIMENTATION EN GAZ Pour une utilisation avec du gaz naturel ou au gaz propane selon l option que vous avez comman...

Страница 16: ...quali Le volet motoris contr l thermiquement est un dispositif d conomie d nergie con u pour une installation dans les vents d appareils au gaz num r s quip s d un coupe tirage Amortisseur conomisedel...

Страница 17: ...Centre de connecteur la paroi lat rale 483mm Retour connecteur pour mur 368mm Centre de connecteur l arri re mur 483mm INSTALLATION EN COIN Unit au mur adjacent 76mm Connecteur Wall Adjacent 368mm Ce...

Страница 18: ...8 x 305mm partie de connecteur GF 1B ex la vanne d arr t 7 Assurez vous que la vanne de gaz est ferm Tournez sur l approvisionnement en gaz et test pour les fuites en utilisant une solution d eau savo...

Страница 19: ...sembl e base GF3 capot GF2 GF3 Page 19 Instructions d installation Suite ENSEMBLE UNIT GF2 A Placez le section de corps dans la base Aligner l ouverture avec le couvercle de commande B Placez le capuc...

Страница 20: ...z le connecteur de glissement tuyau la bo te de support Ins rez le connecteur de glissement tuyau dans la zone de support et tourner pour verrouiller en place Glissez la section du milieu sur la secti...

Страница 21: ...raises de la vermiculite Apr s avoir allum l unit propager les braises acheive un effet encore du charbon 3 La place des b ches comme indiqu en utilisant les boutons d alignement sur les journaux 4 Al...

Страница 22: ...service quali pour inspecter l appareil et pour remplacer toute pi ce du sys t me de contr le et toute commande de gaz qui a t sous l eau INSTRUCTIONS D ALLUMAGE 1 ARR TEZ Lire les consignes de s curi...

Страница 23: ...se assurer que le ux d air de combustion ne est pas obstru 4 Si vous ne savez pas comment effectuer ces proc dures d entretien ont une personne de ser vice sur le terrain quali de v ri er l appareil a...

Страница 24: ...ert Shaw PG9 11 MV 11 Piezo Lighter Electrode 12 MV 12 Pilot Hood 13 MV 13 Thermopile Robert Shaw 6 13 12 11 10 9 8 7 5 3 2 1 4 GF2 3 5 1 15 Le r glage de la amme pilote se trouve sur le dessus de la...

Страница 25: ...RAL GAS 3 5 WC MAX 1 2 PSI FOR MILIVOLT SYSTEM ONLY LP PROPANE CONVERSION KIT 10 WC TH TP TP TH RED WHITE BLACK HIGH LIMIT SWITCH OPTIONAL WALL SWITCH THERMOSTAT OR REMOTE GF2 GF3 Page 25 CUT IF SWITC...

Страница 26: ...a 95404 707 523 7755 Fax 707 577 8036 www malmfireplaces com info malmfireplaces com Obtura teur d air r glable 2 Avant Connexion 1 Retour Connexion R glez amme de la veilleuse a n que la amme voy age...