You should see the USB Serial Ports on your computer with the COM port number
following. Note how mine says COM5.
You can select that port and modify the properties if required, (my software will do that
automatically) but if you feel the urge then the following are the settings for the Signature
Camera:
Communication Speed:
19200
Data length:
8 bit
Parity:
None
Stop Bit:
1 bit
Flow control:
None
If you get a popup message about a “
connection error with serial I/O in the message
”
whenever you press a button, this means that the COM port is not communicating
with the program. Just recheck connections.