Pay attention to not damaging the electric cables and water pipes inside the wall
while making holes on wall for boiler mounting plate.
Electric shock as a result of the contact with electrical items.
Flood risk resuls from water pipe puncture.
Suitable profiled cables must be used in all electric connections.
Fire risk results from overheated law profiled cables.
1.3 GENERAL EXPLANATIONS
MAKTEK Electric Boiler provides the heating by central boiler heating system and with
radiators connected to the system and provides hot water by heat exchanger.
Installation and services must be in accordance with recent standarts and announced
directives. Our company is not responsible for damages caused from wrong
installation and usage.
Make sure the boiler is operated only to comply the intended use of the boiler. Any
usage which does not comply with the boiler's intended use may cause serious injury,
death or harms to the environment and goods.
ATTENTION ;
Only Autorised Services and Manufacturer are responsible for the
boiler.Do not allow other people to interfere with the settings of the boiler.
1.4 C.O.S.H.H
Materials used in the manufacture of this appliance are non-hazardous and no special
precautions are required when fitting or servicing this appliance.
1.5 PREPARATION
1.5.1 Load Check
A load check should be taken into consideration when installing high output boilers.
1.5.2 Boiler Location
The boiler must be installed on a wall that will provide an adequate fixing, and should
be installed in a location that the boiler and pipe-work are not subject to frost and
damp conditions.
1.5.3 Central Heating Installation
Detailed recommendations are given in EN 12828.
Pipes forming part of the useful heating surface should be insulated to prevent any
potential heat loss or frost damage.
Drain valves should be fitted at the lowest point of the system pipe work in an
accessible position.
Содержание OMEGA
Страница 1: ...rev no 02 23 08 2019...
Страница 16: ...13...
Страница 31: ...28 5 3 TROUBLESHOOTING...
Страница 34: ...31 7 TECHNICAL TABLE...
Страница 36: ...10 EXPLODED VIEW 6 40kW MODELS 33 1 2 3 4 5 6 7 8 9 10 11 12 13 15 16 17 18 19 20 21 22 14 23 25 26 27 24...
Страница 38: ...10 2 HYDROLIC GROUP DETAIL 35 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 59 57 58 60 62 61 63 65 64...
Страница 39: ...10 3 RELAY BOARD GROUP DETAIL 36 66 67 68 69 70 71 72...
Страница 42: ...11 1 MAIN HEAT EXCHANGER GROUP DETAIL 39 31 32 34 33 35 36 37 42 43 44 46 38 39 40 41 45...
Страница 43: ...11 2 RELAY BOARD GROUP DETAIL 40 47 48 49 50 51 52 53 54...