If the 

regulator’s control 

operation is switched off, a dot is displayed on the regulator's 

display (factory settings). By changing the parameter 

d1

 (see 6. PROGRAMMING) from 

the  value  0  for  value  1,  when  the  regulator  is  switched  off,  the  display  will  show  the 
current measured temperature.

 

 

 

 
 

4. SCHEME OF CONNECTION OF THE REGULATOR.

 

In  order  to  connect  the  regulator  to  the  device  with  which  it  is  to  be  controlled,  
the following should be done: 

 

prepare the hole in the refrigeration device to install the regulator 
 

 

 

place the regulator in the prepared hole and screw it in properly, 

 

place  the  temperature  sensor  inside  the  cooling  chamber  in  the  most  convenient 
place for temperature measurement and at the same time shielded from accidental 
damage, 

 

connect the regulator to the outputs located on the rear wall of the casing, according 
to the following scheme: 

 

Содержание SMT-01

Страница 1: ...rature measuring range between 40 OC and 120 OC control temperature range between 40 OC and 120 OC decreased by a set hysteresis measuring resolution of the temperature measurer resolution of control...

Страница 2: ...er ventilator 10 A 250 V AC power supply 230 V AC 50 HZ protection class IP 55 safety class CE 3 CONSTRUCTION Regulator SMT is placed in a compact casing including all control and executive elements T...

Страница 3: ...own depending on the type of regulator The regulator SMT 02H v 3 apart from cable entry through glands has a sealing connection of the front part of the casing with its back which ensures splash proof...

Страница 4: ...LATOR In order to connect the regulator to the device with which it is to be controlled the following should be done prepare the hole in the refrigeration device to install the regulator place the reg...

Страница 5: ...d temperature parameter C9 is set to the value 0 3 Light signaling function for switching on the cooling heating operation blue LED is on 4 Control function of the heating system depending on the meas...

Страница 6: ...g visual and audible of exceeding the set temperature range parameters HA and HE This function is connected with the possibility of delaying the time of switching on the alarm system of the regulator...

Страница 7: ...motoreducer The work for the control settings of the refrigeration system will be discussed below ATTENTION Parameter dE is the delay of switching on the unit and the stirrer after switching on the re...

Страница 8: ...e difference at which the switching off occurs and then the unit is switched on For example if the control temperature is set to 4 OC and hysteresis to 2 OC then the unit will be switched off after re...

Страница 9: ...lapses the manual operation of the stirrer is switched off ATTENTION No light signaling of the stirrer operation 7 8 when the regulator is switched off means that the automatic stirrer operation has b...

Страница 10: ...e delay time of enabling this function allows for pre cooling of the milk after the start of cooling and thus not taking into account the maximum temperature when the device is started This time shoul...

Страница 11: ...in the initial cooling phase Exceeding the set temperature range is signaled visually and sound In the event of activation of the alarm the buzzer is triggered cyclically every 1 minute for 5 seconds...

Страница 12: ...to 120 OC every 1 0 OC 10 OC control hysteresis HI the possibility of setting the temperature from 0 2 OC to 10 OC every 0 2 OC for the range from 10 OC to 100 OC and from 1 0 OC to 10 OC every 1 0 OC...

Страница 13: ...1 the possibility of setting the temperature from 40 OC to 120 OC every 1 0 OC 2 OC upper temperature of the alarm A2 the possibility of setting the temperature from 40 OC to 120 OC every 1 0 OC 12 OC...

Отзывы: