1. DESCRIPTION. 

Temperature  regulators  of  SMT  series  are  a  microprocessor-based,  programmable 
temperature  controllers,  intended  for  use  i.a.  in  milk  coolers  and  all  types  of  dryers.  
The series includes the following regulators: 

 

SMT-01, 

 

SMT-02, 

 

SMT-02H, 

 

SMT-03. 

Individual  types  differ  from  each  other  in  the  way  of  output  of  control  inputs  and 
outputs. The casing of regulators in this series are adapted for panel mounting. 
 
 

2. TECHNICAL DATA. 

temperature measuring range 

between -40 

O

C and +120 

O

control temperature range 

between -40 

O

C and +120 

O

C  

(decreased by a set hysteresis) 

measuring resolution of the 
temperature measurer (resolution 
of control temperature settings) 

O

C for the range below -9,9 

O

0,2 

O

C for the range from -10 

O

C to +100 

O

C  

O

C for the range over +100 

O

control hysteresis 
[programmable parameter] 

between 0,2 

O

C and 10 

O

C for the range from -10 

O

C to +100 

O

between 1 

O

C and 10 

O

C for the range  <-10 

O

C and >+100 

O

working time of the stirrer 
(ventilator) 
[programmable parameter] 

between 1 min. and 60 min. 

standstill time of the stirrer 
(ventilator) 
[programmable parameter] 

between 1 min. and 60 min.  

temporary work time of the stirrer 
(ventilator) 
[programmable parameter] 

between 1 min. and 60 min. 

time delay for switching the unit / 
stirrer on after the regulator is 

between 1 s. and 999 s. 

Содержание SMT-01

Страница 1: ...rature measuring range between 40 OC and 120 OC control temperature range between 40 OC and 120 OC decreased by a set hysteresis measuring resolution of the temperature measurer resolution of control...

Страница 2: ...er ventilator 10 A 250 V AC power supply 230 V AC 50 HZ protection class IP 55 safety class CE 3 CONSTRUCTION Regulator SMT is placed in a compact casing including all control and executive elements T...

Страница 3: ...own depending on the type of regulator The regulator SMT 02H v 3 apart from cable entry through glands has a sealing connection of the front part of the casing with its back which ensures splash proof...

Страница 4: ...LATOR In order to connect the regulator to the device with which it is to be controlled the following should be done prepare the hole in the refrigeration device to install the regulator place the reg...

Страница 5: ...d temperature parameter C9 is set to the value 0 3 Light signaling function for switching on the cooling heating operation blue LED is on 4 Control function of the heating system depending on the meas...

Страница 6: ...g visual and audible of exceeding the set temperature range parameters HA and HE This function is connected with the possibility of delaying the time of switching on the alarm system of the regulator...

Страница 7: ...motoreducer The work for the control settings of the refrigeration system will be discussed below ATTENTION Parameter dE is the delay of switching on the unit and the stirrer after switching on the re...

Страница 8: ...e difference at which the switching off occurs and then the unit is switched on For example if the control temperature is set to 4 OC and hysteresis to 2 OC then the unit will be switched off after re...

Страница 9: ...lapses the manual operation of the stirrer is switched off ATTENTION No light signaling of the stirrer operation 7 8 when the regulator is switched off means that the automatic stirrer operation has b...

Страница 10: ...e delay time of enabling this function allows for pre cooling of the milk after the start of cooling and thus not taking into account the maximum temperature when the device is started This time shoul...

Страница 11: ...in the initial cooling phase Exceeding the set temperature range is signaled visually and sound In the event of activation of the alarm the buzzer is triggered cyclically every 1 minute for 5 seconds...

Страница 12: ...to 120 OC every 1 0 OC 10 OC control hysteresis HI the possibility of setting the temperature from 0 2 OC to 10 OC every 0 2 OC for the range from 10 OC to 100 OC and from 1 0 OC to 10 OC every 1 0 OC...

Страница 13: ...1 the possibility of setting the temperature from 40 OC to 120 OC every 1 0 OC 2 OC upper temperature of the alarm A2 the possibility of setting the temperature from 40 OC to 120 OC every 1 0 OC 12 OC...

Отзывы: