W
iring diagram
P 9 / 9
Rib F
Rib E
[3] Wiring of Other Lead Wires When Choke Coils Are Not Used
Fig. 13
*Connect lead wire from choke coil (purple)
with brush holder using insulated connector.
(See Fig. 13A below.)
Lead wire of noise
suppressor (clear)
Route between
rib E and rib F.
Lead wire from choke coil
to brush holder (orange)
Route between rib E and rib F.
Boss A
Be careful not to pinch the following
lead wires between boss A and
handle cover:
*Lead wire of Brush holder (purple)
*Lead wire of Brush holder (orange)
**Connect lead wire from choke coil (orange)
with brush holder using insulated connector.
(See Fig. 13A below.)
Bend the insulated connectors in the direction opposite to switch
as illustrated below.
Fig. 13A
**Connector with brush holder
lead wire (orange) assembled
*Insulated connector with brush
holder lead wire (purple) assembled
Switch
The end of bent insulated connector
must not positioned over this line.
Brush holder