[2] Removing motor unit (blade case, motor housing, handle etc.) from front arm complete
Remove hex bolt M6x14 from center cover.
2. Remove the screws in
Fig. 3-4
to disconnect the linkage of motor unit and front arm complete.
Lock the motor unit by pushing k
nob 20 for stopper pin
while keeping the motor unit at the rest position.
Knob 20
Stopper pin
Fig. 3-1
Fig. 3-2
Fig. 3-3
Fig. 3-4
Turn safety cover and then open center cover as illustrated
above. + flat head screw M5 comes into sight at that time.
The safety cover section can be separated from motor unit
by removing the + flat head screw M5.
Center cover
Safety cover
+ Flat head screw M5
Hex socket headbolt M6x10
(for securing pipe16-90)
Link plate
Ring 6
Flat washer 6
Hex socket head bolt M6x20
(for fixing link plate)
Center cover
Hex bolt M6x14
R
epair
P
5
/ 2
6
1. Remove safety cover section from blade case as illustrated in