18 ENGLISH
NOTE:
To empty the tank completely, tilt the main unit
slightly toward the outlet of hose.
Cleaning the machine
NOTICE:
Never use gasoline, benzine, thinner,
alcohol or the like. Discoloration, deformation or
cracks may result.
Clean the machine by wiping off dust with a dry cloth or
one dipped in soapy water and wrung out.
Remove dust or dirt from the suction inlet.
1
Fig.36
►
1.
Suction inlet
Cleaning the filter
Clean the filter regularly. To clean the filter, follow the
steps below.
1.
Remove the battery cartridges, and then close the tank lever.
2.
Remove the filter cap by turning it counterclock
-
wise, and then remove the filter.
2
1
Fig.37
►
1.
Filter cap
2.
Filter
3.
Clean the filter with running water.
4.
Attach the filter to the main unit, and then tighten
the filter cap.
5.
Open the tank lever.
Storage
Before storing the machine, perform full maintenance.
Store the machine in a place out of the reach of children
and not exposed to moisture, rain, or direct sunlight.
You can connect the band of the pipe to the machine as
shown in the figure to stand up the pipe.
1
Fig.38
►
1.
Band
Changing the nozzle
You can change the standard nozzle to the ULV (Ultra
Low Volume) nozzle. The ULV nozzle can discharge
finer mist than the standard nozzle. To change the
nozzle, follow the steps below.
1.
Loosen the screw and remove it, and then remove
the front side of the end nozzle.
1
2
Fig.39
►
1.
Screw
2.
End nozzle