background image

7

ENGLISH

FUNCTIONAL 
DESCRIPTION

CAUTION:

 

Always be sure that the tool is 

switched off and the battery cartridge is removed 

before adjusting or checking function on the tool.

Installing or removing battery 
cartridge

CAUTION:

 

Always switch off the tool before 

installing or removing of the battery cartridge.

CAUTION:

 

Hold the tool and the battery car-

tridge firmly when installing or removing battery 

cartridge.

 Failure to hold the tool and the battery 

cartridge firmly may cause them to slip off your hands 

and result in damage to the tool and battery cartridge 

and a personal injury.

To install the battery cartridge, align the tongue on the 

battery cartridge with the groove in the housing and slip 

it into place. Insert it all the way until it locks in place 

with a little click. If you can see the red indicator as 

shown in the figure, it is not locked completely.
To remove the battery cartridge, slide it from the tool 

while sliding the button on the front of the cartridge.

1

2

3

Fig.1

►    

1.

 Red indicator 

2.

 Button 

3.

 Battery cartridge

CAUTION:

 

Always install the battery cartridge 

fully until the red indicator cannot be seen.

 If not, 

it may accidentally fall out of the tool, causing injury to 

you or someone around you.

CAUTION:

 

Do not install the battery cartridge 

forcibly.

 If the cartridge does not slide in easily, it is 

not being inserted correctly.

Battery protection system

The tool is equipped with a battery protection system. 

This system automatically cuts off power to the motor to 

extend battery life.

The tool will automatically stop during operation if the 

tool and/or battery are placed under one of the following 

conditions:

Overload protection

The tool is operated in a manner that causes it to draw 

an abnormally high current.

In this situation, turn the tool off and stop the application 

that caused the tool to become overloaded. Then turn 
the tool on to restart.

If the tool does not start, the battery is overheated. In 

this situation, let the battery cool before turning the tool 

on again.

Overdischarge protection

The remaining battery capacity is too low and the tool 

will not operate. In this situation, remove and recharge 

the battery.

Protections against other causes

Protection system is also designed for other causes 

that could damage the tool and allows the tool to stop 

automatically. Take all the following steps to clear the 

causes, when the tool has been brought to a temporary 

halt or stop in operation.

1.  Turn the tool off, and then turn it on again to 

restart.

2.  Charge the battery(ies) or replace it/them with 

recharged battery(ies).

3.  Let the tool and battery(ies) cool down.
If no improvement can be found by restoring protection 

system, then contact your local Makita Service Center.

Indicating the remaining battery 
capacity

Only for battery cartridges with the indicator

1

2

Fig.2

►    

1.

 Indicator lamps 

2.

 Check button

Press the check button on the battery cartridge to indi

-

cate the remaining battery capacity. The indicator lamps 

light up for a few seconds.

Содержание DTW1004

Страница 1: ...INSTRUCTION MANUAL Cordless Impact Wrench DTW1001 DTW1002 DTW1004 DTW800 DTW1001XV DTW1002XV DTW1004XV DTW800XV ENGLISH Original instructions Read before use...

Страница 2: ...0B BL1850B BL1860B Charger DC18RC DC18RD DC18RE DC18SD DC18SE DC18SF DC18SH DC18WC Some of the battery cartridges and chargers listed above may not be available depending on your region of residence W...

Страница 3: ...tainty K 1 5 m s 2 Model DTW1004 DTW1004XV Work mode impact tightening of fasteners of the maxi mum capacity of the tool Vibration emission ah 18 4 m s 2 Uncertainty K 1 7 m s 2 Model DTW800 DTW800XV...

Страница 4: ...eft attached to a rotating part of the power tool may result in personal injury 5 Do not overreach Keep proper footing and balance at all times This enables better control of the power tool in unexpec...

Страница 5: ...only be performed by the manufacturer or authorized service providers 3 Follow instruction for lubricating and chang ing accessories Cordless impact wrench impact drill safety warnings For impact wre...

Страница 6: ...d in the packaging 11 When disposing the battery cartridge remove it from the tool and dispose of it in a safe place Follow your local regulations relating to disposal of battery 12 Use the batteries...

Страница 7: ...quipped with a battery protection system This system automatically cuts off power to the motor to extend battery life The tool will automatically stop during operation if the tool and or battery are p...

Страница 8: ...ool serviced at a Makita service center Lighting up the front lamp CAUTION Do not look in the light or see the source of light directly To turn on the lamp status press the button for one second To tu...

Страница 9: ...Fig 6 1 Reversing switch lever Changing the impact force You can change the impact in three steps hard medium and soft mode This allows a tightening suitable to the work Every time the button is press...

Страница 10: ...and the battery cartridge is removed before carrying out any work on the tool Selecting correct impact socket Always use the correct size impact socket for bolts and nuts An incorrect size impact soc...

Страница 11: ...e impact socket simply pull it off If it is hard to remove depress the detent pin while pulling the impact socket 1 2 3 4 Fig 10 1 Impact socket 2 Hole 3 Square drive 4 Detent pin Installing or removi...

Страница 12: ...to hang the tool securely before releasing your hold Insufficient or unbalanced hooking may cause falling off and you may be injured The hook is convenient for temporarily hanging the tool This can b...

Страница 13: ...200 2040 4080 6120 8160 N m kgf cm 2 1 M24 M24 M22 M22 M20 M20 1 Fastening time second 2 Fastening torque Model DTW1002 DTW1002XV Proper fastening torque for standard bolt 1 2 N m kgf cm 800 600 400 2...

Страница 14: ...0 600 400 200 2040 4080 6120 8160 N m kgf cm 2 1 M24 M24 M22 M22 M20 M20 1 Fastening time second 2 Fastening torque Model DTW800 DTW800XV Proper fastening torque for standard bolt N m kgf cm 1 1 0 2 3...

Страница 15: ...nsion bar somewhat reduces the fastening force of the impact wrench Compensate by fastening for a longer period of time 5 The manner of holding the tool or the material of driving position to be faste...

Страница 16: ...Makita Europe N V Jan Baptist Vinkstraat 2 3070 Kortenberg Belgium Makita Corporation 3 11 8 Sumiyoshi cho Anjo Aichi 446 8502 Japan 885A47 225 EN 20230523...

Отзывы: