12
NOTE:
• Dust may spill out when capsule is opened, so be sure
to set a garbage bag beneath capsule.
Remove accumulated dust from inside of capsule and off
of high performance filter.
(Fig. 12)
Twist high performance filter in direction of arrow to
unfasten securing lip from cleaner unit and then pull off
the filter.
(Fig. 13)
Clean out the fine dust and lightly tap to dislodge dust
from high performance filter.
Reassembly
Reassembly for normal filter
Put on filter until it is fully in position on the cleaner unit.
(Fig. 14)
NOTE:
• Make sure filter is put on straight without being peeled
back. If filter is put on incorrectly as shown in diagram,
dust will get into motor housing, and cause motor fail-
ure.
(Fig. 15)
Connect prefilter. At this time, make sure to twist prefilter
so that securing lip is firmly locked into cleaner unit.
(Fig. 16 & 17)
Connect capsule. Align O symbol on capsule with O sym-
bol on handle and then firmly twist capsule in direction of
arrow until it is secured.
(Fig. 18 & 19)
NOTE:
• Always remove dust ahead of time, as suction power
will be reduced if there is too much dust in cleaner.
• Always be sure to check that both filter and prefilter are
loaded correctly prior to using cleaner. If they are not
loaded correctly, dust will get into the motor housing,
and cause motor failure.
If the following examples occur, filter and prefilter are
not loaded correctly. Reload them correctly to rectify
problem.
Problem Examples
Example 1: Only prefilter has been loaded (no filter)
(Fig. 20)
Example 2: Only filter has been loaded (no prefilter)
(Fig. 21)
Example 3: Filter has been loaded in a peeled back state
(Fig. 15)
Example 4: Prefilter’s securing lip is not firmly locked into
groove of cleaner housing
(Fig. 22)
Reassembly for high performance filter
Connect high performance filter. At this time, make sure
to twist high performance filter so that securing lip is
firmly locked into cleaner unit.
(Fig. 23 & 24)
Connect capsule. Align O symbol on capsule with O sym-
bol on handle and then firmly twist capsule in direction of
arrow until it is secured.
(Fig. 25 & 19)
NOTE:
• Always remove dust ahead of time, as suction power
will be reduced if there is too much dust in cleaner.
• Always be sure to check that high performance filter is
loaded correctly prior to using cleaner. If they are not
loaded correctly, dust will get into the motor housing,
and cause motor failure.
If the following examples occur, high performance filter
is not loaded correctly. Reload them correctly to rectify
problem.
Problem Examples
Securing lip of high performance filter is not firmly locked
into groove of cleaner housing.
(Fig. 26)
OPERATION
CAUTION:
• To connect attachments, such as nozzle, twist-insert
attachment in direction of arrow to ensure secure con-
nection during use. To disconnect attachment, twist-
extract also in direction of arrow.
If attachment is twisted in the opposite direction, when
being connected or disconnected, capsule may
become loose.
(Fig. 27)
Cleaning (Suction)
Nozzle (Fig. 28)
Attach the nozzle to clean off tables, desks, furniture, etc.
Nozzle slips on easily.
Extension wand (Straight pipe) (Fig. 29)
The extension wand fits in between the nozzle and the
cleaner itself. This arrangement is convenient for
cleaning a floor while standing erect.
Corner nozzle (Fig. 30)
Fit on the corner nozzle for cleaning corners and
crevices of a car or furniture.
Corner Extension wand (Straight pipe)
(Fig. 31)
In tight quarters where the cleaner itself cannot squeeze
in, or in high places hard to reach, use this arrangement.
Cleaning without nozzle (Fig. 32)
You can pick up powder and dust without nozzle.
MAINTENANCE
CAUTION:
• Always be sure that the tool is switched off before
attempting to perform inspection or maintenance.
Cleaning
NOTICE:
•
Never use gasoline, benzine, thinner, alcohol or the
like. Discoloration, deformation or cracks may
result.
•
Do not blow dust sticking on the cleaner and filters
by air duster.
It brings dust into the housing and
causes failure.
•
After washing filters, dry them thoroughly before
use.
Insufficiently dried filters may cause poor suction
and shorten the service life of the motor.
•
After cleaning filters and sponge filter, be sure to
re-install them before use.
If you use the cleaner
without filters and sponge filter, dust comes into the
motor housing and cause malfunction.
Cleaner body
From time to time wipe off the outside (cleaner body) of
the cleaner using a cloth dampened in soapy water.
Clean out also the suction opening and filter mounting
area.
(Fig. 33)
Filter
Wash the filter in soapy water when it is clogged with
dust and the cleaner power becomes weak. Dry it out
thoroughly before use.
(Fig. 34)
Содержание DCL180SY
Страница 6: ...6 21 22 33 34 36 35 37 010008 010009 1050603 1043806 23 24 25 12 1206607...
Страница 7: ...7 38 39 40 41 42 27 28 26 29 28 27 27 29 1206610 1206609 1206608 29 30 30 29 31 1206611 1206612...
Страница 67: ...67 ENE017 1 ENA007 3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 130 C 21 Ni MH Li ion...
Страница 68: ...68 ENB127 1 1 2 3 4 5 6 ENC007 17 1 1 2 3 2 3 4 5 1 2 3 6 50 C 7 8 9 10 11 12 Makita 13 14 15 16...
Страница 69: ...69 17 18 Makita Makita Makita Makita 1 2 3 10 C 40 C 4 5 1 2 3 OFF DCL180F 4 5...
Страница 70: ...70 6 7 4 5 8 9 10 11 4 5 8 12 13 14 15 16 17 18 19 75 100 50 75 25 50 0 25...
Страница 71: ...71 1 20 2 21 3 15 4 22 23 24 O O 25 19 26 27 28 29 30 31 32 33 34 1 2 3 4 35...
Страница 72: ...72 36 010051 Makita Makita Makita Makita Makita 37...
Страница 73: ...73 1 38 2 3 39 40 1 41 2 3 42...
Страница 74: ...74...
Страница 75: ...75...