P 4/16
[3] DISASSEMBLY/ASSEMBLY
[3] -1. Casing Assembly and Feeder Box Assembly
R
epair
DISASSEMBLING
Clamper
Clamper
Casing complete
Casing complete
4) Clamper and Compression spring 23 can now be
removed from Casing complete.
Fig. 2
Fig. 3
Fig. 4
Disassemble by taking the steps described in Fig. 2 to Fig 17.
2) Then pull off Casing
assembly from Housing.
Casing assembly
3) While pressing Clamper, remove three M4x12 Countersunk
head screws from Casing complete.
1) Loosen Thumb screw M4x28
by turning counterclockwise.
Countersunk head screw M4x12:
one on Thumb screw M4x28 side, two on the opposite side
No.1 Phillips
screwdriver
(+) Shoulder flat head screw M3x5
Fig. 6
Fig. 5
Compression spring 23
Clamper
Removing Insulation sleeve from Clamper
While pressing two of the three locking tabs of Insulation
sleeve inward using 1R291, push it off from Clamper.
Clamper
Insulation sleeve
1R291
5) Stopper on either side of Casing complete can be
removed by sliding it in the direction of the gray
arrow while lifting up its rear end with a slotted
screwdriver.
6) Remove (+) Shoulder flat head screw M3x5
together with Sleeve 4 using No.1 Phillips screwdriver.
rear end
of Stopper
rear end of Stopper
Sleeve 4