Panel Controls
1.
CHannel 1 Signal INput:
Direct-coupled signal input capable of accepting audio or control signals. Range of up to 10Vpp.
2.
CHannel 1 DAMP CV INput:
CV input for the CHannel’s DAMPing parameter, now capable of accepting audio or control
signals. Normalized to +8V so that with nothing patched, the CHannel 1 DAMP Combo Pot operates as a manual control
for the parameter. Range 0V-8V.
3.
CHannel 1 CONTROL INput:
Direct coupled, highly-sensitive CV input for the CHannel’s vactrol VCA. Normalized to +8V so
4.
CHannel 1 DAMP Combo Pot:
Unipolar attenuator for DAMP CV INput. With nothing patched to the DAMP CV INput,
operates as a manual control for the DAMP parameter.
5.
CHannel 1 Combo Pot:
Unipolar attenuator for CONTROL Signal INput. With nothing patched to the CHannel 1 Control
6.
CHannel 1 Signal OUT:
Output of the signal applied to the CHannel 2 input, as processed by the LPG. 10Vpp (depending
upon settings and source material).
7.
CHannel 1 STRIKE INput:
Gate INput for striking or plucking the vactrol. Expects 8V Gate.