5
8
11
14
15 16
13
12
10
9
Panel Controls (cont’d)
8.
CHannel 2 Signal INput:
Direct-coupled signal input capable of accepting audio or control signals. Range of up to 10Vpp.
9.
CHannel 2
Control Signal INput:
Direct-coupled, highly-sensitive CV input for CHannel 2’s vactrol VCA. Normalized to +8V so
10.
CHannel 2 DAMP CV INput:
INput for CHannel 2’s DAMP parameter, now capable of receiving audio or control signals.
Normalized to +8V so that with nothing patched, the CHannel 2 DAMP Combo Pot operates as a manual control for the
parameter. Range 0V-8V.
11.
CHAnnel 2 DAMP Combo Pot:
Unipolar attenuator for CHannel 2 DAMP CV INput. With nothing patched to the CHannel 2
DAMP CV INput, operates as a manual control for the parameter.
12.
CHannel 2 CONTROL Combo Pot:
Unipolar attenuator for CHannel 2 CONTROL Signal INput. With nothing patched to the
13.
CHannel 2 Signal OUTput:
Direct-coupled OUTput of the Signal applied to the CHannel 2 INput, as processed by the LPG.
10Vpp (depending upon gate settings and source material).
14.
CHannel 2 STRIKE INput:
Gate INput for striking or plucking the CHannel 2 CONTROL vactrol. Expects 8V Gate.
15.
AUXiliary INput:
Direct-coupled signal input to the SUM circuit, allowing for the chaining of multiple Optomix and modDemix
units to create larger mixes. Capable of accepting audio or control signals up to 10Vpp.
16.
SUM OUT:
The SUM or mix of all signals processed by the OPTOMIX is output at this jack. 10Vpp (depending upon settings
and source material).
Содержание Optomix
Страница 1: ...v2 4 ...