Submenu 1 

 Output  

The merger offers the possibility to reduce the data transmission speed 
of the output. This can often solve problems such as flickering or total 
failure with extremely old DMX devices in the network. 

After entering the submenu 1 (OUTPUT SPEED), the following display 
appears: 
 

OUTSPEED  

FAST >44 

Mode 1, 

or

 

OUTSPEED  

MED. >33 

Mode 2, 

or

 

OUTSPEED  

SLOW >22 

Mode 3 

 
The right "UP/DOWN" - keys change as often as desired between these 

3 settings, the left, lower „

OK

 - key saves the current selection. 

You can cancel and return to the main menu with "MENU / ESC" - key.  

The repetition rates of the DMX output signal are approximate only.  

Also, the output signal is not simply slowed down by a waiting time at the 
end of each data stream.  

This would not have a positive effect, as experience has shown that 
receivers with problems with too high transmission speed also require 
longer break and signal times within the data stream, for example: 

 

 

a longer BREAK signal, 

 

a longer delay afterwards (MAB - MARK AFTER BREAK), 

 

a break between the data words (MBS - MARK BETWEEN 
SLOTS), and 

 

a break after the last data word before a new data stream starts 
with BREAK (MBB - MARK BEFORE BREAK) 

 

The following table shows the times currently used in the three speed 
variants: 

 

 

 

Содержание 4001733

Страница 1: ...Major DMX Merger 3in1 User Manual...

Страница 2: ...rm nor by photos or electronic media Delivery options and all technical specifications are subject to change without notification We do not assume liability for any incorrect information in this docum...

Страница 3: ...llation 4 2 Standard Operating Mode Display 5 3 Termination Switch 6 4 Configuration 7 5 Submenu 1 Output 9 6 Submenu 2 Merge Modus 11 7 Submenu 3 4 5 DMX insert address for input A B C 12 8 Submenu 7...

Страница 4: ...d LEDs on the front of the device flash briefly from left to right during the self test Then the yellow RDM LED for input B flashes to indicate the main version number of the firmware currently loaded...

Страница 5: ...e front for visualizing the main device function for each input The status of each input where a valid DMX signal is present is indicated by slow flashing of the assigned green DMX LED If RDM communic...

Страница 6: ...MINATION which allows the user to simply connect the terminating resistor 120 Ohm in position I on the right required at the end of a DMX line However if the respective signal line runs further from t...

Страница 7: ...enus are also lost After the first press of the left MENU key the first submenu is proposed for selection Use the two UP DOWN keys to the right of the display to scroll to the desired submenu item in...

Страница 8: ...NU ESC key automatically returns the unit to the STANDARD OPERATING MODE To enter the desired submenu press the OK key at the bottom left Please notice Even after entering the menu level the device co...

Страница 9: ...cancel and return to the main menu with MENU ESC key The repetition rates of the DMX output signal are approximate only Also the output signal is not simply slowed down by a waiting time at the end of...

Страница 10: ...te BREAK LENGTH MAB MARK AFTER BREAK MBS MARK BETWEEN SLOTS MBB MARK BEFORE BREAK PERIOD TIME REFRESH RATE 44 Hz 92 s 12 s 44 s 22 7 ms 44 0 Hz 33 Hz 176 s 24 s 16 s 176 s 31 1 ms 32 1 Hz 22 Hz 220 s...

Страница 11: ...In practice this allows parallel operation while simultaneously ensuring a possible minimum level for each input channel safety function emergency light through light etc MODE 1 LoTP display shows LO...

Страница 12: ...rge lighting console controls at input A the entire DMX area of one event location A second smaller lighting console has access to the lighting circuits of the foyer at input B from DMX 301 but via it...

Страница 13: ...Y PERM ON If it is set to PERMANENT ON or DISPLAY AUTO OFF if it switches AUTOMATICALLY OFF If the AUTO OFF function is activated the display is switched off after a period of approx 30 seconds withou...

Страница 14: ...perating device does not have a separate power switch Also any held channels in HTP or LoTP mode of a source that has meanwhile been switched off or staked out are reset Electrical data Approvals 2006...

Страница 15: ...n1 X LR5 4002164 DMX Merger 3in1 RJ45 We hereby certify that the above nam ed product s as we put the execution into circulation is are conform with the regulations of the following EU directives Low...

Страница 16: ...16 Version 1 05 05 10 18...

Отзывы: