Range
40.00A
400.0A
Accuracy ±(% of digits)
±(2.0% + 8 digits)
±(2.5% + 8 digits)
Function
DC Current
Over range protection: Maximum input 400A.
Resolution
10mA
100mA
Range
40.00A
400.0A
Accuracy ±(% of digits)
±(2.0% + 8 digits)
±(2.5% + 8 digits)
Function
AC True RMS Current
Over range protection: Maximum input 400A.
Accuracy specified from 5% to 100% of the measuring range.
Frequency Response: 50Hz to 60Hz True RMS.
Inrush current Maximum Input: 400A Inrush current Sensitivity: >2A.
Resolution
10mA
100mA
7
5. Specifications
400.0V
±(1.0% + 3 digits)
100mV
1000V
±(1.2% + 3 digits)
1V
Range
4.000V
40.00V
Accuracy ±(% of digits)
±(1.0% + 3 digits)
±(1.0% + 3 digits)
Function
DC Voltage
Maximum input: 1000V DC
Resolution
1mV
10mV
400.0V
±(1.2% + 5 digits)
100mV
1000V
±(1.5% + 5 digits)
1V
Range
4.000V
40.00V
Accuracy ±(% of digits)
±(1.2% + 5 digits)
±(1.2% + 5 digits)
Function
AC True RMS Voltage
Variable frequency Drive TEST AC voltage range: 100V---600V.
AC voltage bandwidth: 50 to 1000Hz (sine) 50/60 (all wave)
Accuracy specified from 5% to 100% of the measuring range
Maximum Input: 1000V AC RMS.
PEAK Maximum Input: 1000V
Resolution
1mV
10mV
(with VFD)
40.00k
Ω
±(1.5% + 2 digits)
10
Ω
400.0k
Ω
±(1.5% + 2 digits)
100
Ω
Range
400.0
Ω
4.000k
Ω
Accuracy ±(% of digits)
±(1% + 4 digits)
±(1.5% + 2 digits)
Function
Resistance
Input Protection: 300V DC or 300V AC RMS
Resolution
0.1
Ω
1
Ω
4.000M
Ω
±(2.0% + 5 digits)
1k
Ω
40.00M
Ω
±(3.0% + 8 digits)
10k
Ω