7. Operation

NOTES:

 Read and understand all Warning and Caution statements in this 

operation manual prior to using this meter. Set the function select switch to 
the OFF position when the meter is not in use.

7.1. AC/DC Current Measurements

 

WARNING:

 Ensure that the test leads are disconnected from the meter 

before making current clamp measurements.

1. Set the Function switch to the 

400A

 range. If the approx. range of the 

measurement is not known, select the highest range then move to the 
lower ranges if necessary.

2. Press the 

REL

 button to zero the meter display.

3. Use Rotary Function switch to select AC or DC 

40A 400A

 range.

4. Use MODE Button to select AC or DC.
5. Select AC current Test, press the INRUSH key to turn Inrush current test, 

the LCD will display "----".

6. Press the trigger to open jaw. Fully enclose only one conductor. For 

optimum results, center the conductor in the jaw.

7.  The clamp meter LCD will display the reading.

CORRECT

INCORRECT

Содержание MT723

Страница 1: ...AC DC TRMS CLAMP METER INSTRUCTION MANUAL MT723 II...

Страница 2: ...2...

Страница 3: ...age Measurement 11 7 3 DC Voltage Measurement 11 7 4 Capacitance Measurements 11 7 5 Frequency Measurements 11 7 6 Resistance 12 7 7 Temperature Measurements 12 7 8 Diode Test 12 7 9 Continuity Measur...

Страница 4: ...V When changing ranges always disconnect the test leads from the circuit under test 1 4 CAUTIONS Improper use of this meter can cause damage shock injury or death Read and understand this user manual...

Страница 5: ...ption 8 COM input jack 9 Data Hold and Backlight button 10 Rotary Function switch 11 MODE select and Flashlight button 12 INRUSH and PEAK button 13 V Diode Continuity CAP TEMP Hz jack 14 Battery Cover...

Страница 6: ...irect Current Voltage Alternating Current Voltage Low battery Milli volts or Volts Voltage Resistance Amperes Current Farad Capacitance Hertz Frequency Percent duty ratio Fahrenheit and Celsius units...

Страница 7: ...40 00V Accuracy of reading digits 1 0 3 digits 1 0 3 digits Function DC Voltage Maximum input 1000V DC Resolution 1mV 10mV 400 0V 1 2 5 digits 100mV 1000V 1 5 5 digits 1V Range 4 000V 40 00V Accuracy...

Страница 8: ...nt Auto ranging Range 45Hz to 1kHz Accuracy of reading digits 1 0 5 digits Function Frequency Sensitivity 20A Auto ranging Range 20 0 to 80 0 Accuracy of reading digits 1 2 10 digits Function Duty Cyc...

Страница 9: ...displayed OL display 3 readings per second nominal Type K thermocouple 10M VDC and VAC True RMS AAC and VAC 2KHZ 5 C to 40 C 41 F to 104 F 20 C to 60 C 4 F to 140 F Max 80 up to 31 C decreasing linea...

Страница 10: ...tch to the 400A range If the approx range of the measurement is not known select the highest range then move to the lower ranges if necessary 2 Press the REL button to zero the meter display 3 Use Rot...

Страница 11: ...e capacitor under test before measuring 1 Set the function switch to the CAP position 2 lnsert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the V C...

Страница 12: ...the MODE button to select F or C WARNING To avoid electric shock be sure the thermocouple probe has been removed before changing to another measurement function 7 8 Diode Test 1 lnsert the black test...

Страница 13: ...the cord to assure placing the tip in close proximity to the live conductor NOTE The detector is designed with high sensitivity Static electricity or other sources of energy may randomly trip the sen...

Страница 14: ...In current test mode Press INRUSH key the inrush current values are measured 7 15 Relative Backlight 1 Press the REL button to zero the display REL will appear in the display The displayed reading is...

Страница 15: ...detergent do not use abrasives or solvents If the meter is not to be used for 60 days or more remove the battery and store it separately 10 Battery Replacement 1 Rotate battery door lock 180 degrees...

Страница 16: ...www major tech com www majortech com au sales major tech com info majortech com au MAJOR TECH PTY LTD South Africa Australia...

Отзывы: