This symbol, adjacent to another symbol or terminal, indicates 

the user must refer to the manual for further information.

This symbol, adjacent to a terminal, indicates that, under 

normal use,hazardous voltages may be present.

 
Double insulation.

Application around and removal from uninsulated hazardous 

live conductors is permitted.

4

1. Safety

!

1.1. lnternational Safety Symbols

1.2. SAFETY NOTES

•   Do not exceed the maximum allowable input range of any function.
•   Do not apply voltage to meter when resistance function is selected.
•   Set the function switch OFF when the meter is not in use.
•   Remove the battery if meter is to be stored for longer than 60 days.

1.3. WARNINGS

•   Set function switch to the appropriate position before measuring.
•   When measuring volts do not switch to current resistance modes.
•   Do not measure current on a circuit whose voltage exceeds 600V.
•   When changing ranges always disconnect the test leads from the circuit 

under test.

1.4. CAUTIONS

!

  Improper use of this meter can cause damage, shock, injury or death. 

Read and understand this user manual before operating the meter.

!

  Always remove the test leads before replacing the battery or fuses.

!

  Inspect the condition of the test leads and the meter itself for any 

damage before operating the meter. Repair or replace if damaged before 
use.

!

  Use great care when making measurements if the voltages are greater 

than 25VAC RMS or 35VDC. These voltages are considered a shock 
hazard.

!

  Always discharge capacitors and remove power from the device under 

test before performing Diode, Resistance or Continuity tests.

!

  Voltage checks on electrical outlets can be difficult and misleading 

because of the uncertainty of connection to the recessed electrical 
contacts. Other means should be used to ensure that the terminals are 
not "live".

!

  If the equipment is used in a manner not specified by the manufacturer, 

the protection provided by the equipment may be impaired.

Содержание MT723

Страница 1: ...AC DC TRMS CLAMP METER INSTRUCTION MANUAL MT723 II...

Страница 2: ...2...

Страница 3: ...age Measurement 11 7 3 DC Voltage Measurement 11 7 4 Capacitance Measurements 11 7 5 Frequency Measurements 11 7 6 Resistance 12 7 7 Temperature Measurements 12 7 8 Diode Test 12 7 9 Continuity Measur...

Страница 4: ...V When changing ranges always disconnect the test leads from the circuit under test 1 4 CAUTIONS Improper use of this meter can cause damage shock injury or death Read and understand this user manual...

Страница 5: ...ption 8 COM input jack 9 Data Hold and Backlight button 10 Rotary Function switch 11 MODE select and Flashlight button 12 INRUSH and PEAK button 13 V Diode Continuity CAP TEMP Hz jack 14 Battery Cover...

Страница 6: ...irect Current Voltage Alternating Current Voltage Low battery Milli volts or Volts Voltage Resistance Amperes Current Farad Capacitance Hertz Frequency Percent duty ratio Fahrenheit and Celsius units...

Страница 7: ...40 00V Accuracy of reading digits 1 0 3 digits 1 0 3 digits Function DC Voltage Maximum input 1000V DC Resolution 1mV 10mV 400 0V 1 2 5 digits 100mV 1000V 1 5 5 digits 1V Range 4 000V 40 00V Accuracy...

Страница 8: ...nt Auto ranging Range 45Hz to 1kHz Accuracy of reading digits 1 0 5 digits Function Frequency Sensitivity 20A Auto ranging Range 20 0 to 80 0 Accuracy of reading digits 1 2 10 digits Function Duty Cyc...

Страница 9: ...displayed OL display 3 readings per second nominal Type K thermocouple 10M VDC and VAC True RMS AAC and VAC 2KHZ 5 C to 40 C 41 F to 104 F 20 C to 60 C 4 F to 140 F Max 80 up to 31 C decreasing linea...

Страница 10: ...tch to the 400A range If the approx range of the measurement is not known select the highest range then move to the lower ranges if necessary 2 Press the REL button to zero the meter display 3 Use Rot...

Страница 11: ...e capacitor under test before measuring 1 Set the function switch to the CAP position 2 lnsert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the V C...

Страница 12: ...the MODE button to select F or C WARNING To avoid electric shock be sure the thermocouple probe has been removed before changing to another measurement function 7 8 Diode Test 1 lnsert the black test...

Страница 13: ...the cord to assure placing the tip in close proximity to the live conductor NOTE The detector is designed with high sensitivity Static electricity or other sources of energy may randomly trip the sen...

Страница 14: ...In current test mode Press INRUSH key the inrush current values are measured 7 15 Relative Backlight 1 Press the REL button to zero the display REL will appear in the display The displayed reading is...

Страница 15: ...detergent do not use abrasives or solvents If the meter is not to be used for 60 days or more remove the battery and store it separately 10 Battery Replacement 1 Rotate battery door lock 180 degrees...

Страница 16: ...www major tech com www majortech com au sales major tech com info majortech com au MAJOR TECH PTY LTD South Africa Australia...

Отзывы: