9
Measurement rate
Operating Temperature
Clamp jaw opening
Over-range indication
AC response
Temperature sensor
ACV Bandwidth
Display
Low Battery indication
Input Impedance
Storage Temperature
Operating Humidity
Operating Altitude
Battery
Auto power OFF
Dimensions
Safety
Battery life
Storage Humidity
Weight
2KHZ
30mm approx.
3-3/4 digits (4000 counts) backlit LCD
‘ ' is displayed
'OL' display
3 readings per second, nominal
Type K thermocouple
10M (VDC and VAC)
True RMS (AAC and VAC)
-20°C to 60°C (-4°F to 140°F)
<80%
Max 80% up to 31°C decreasing linearly to
50% at 40°C
2000 meters maximum.
5°C to 40°C (41°F to 104°F)
220 x 80 x 39mm
305g
EN61010-2-032 EN61010-2-033 Overvoltage
Category lll 600V, Pollution Degree 2.
~30h
(backlight ON),
~100
h (backlight OFF)
After approx. 15 minutes
Three (3) x 1.5V AAA Battery
For indoor use and in accordance with the
requirements for double insulation to
IEC1010-1 (2001): EN61010-2-030
6. General Specifications