1. Set the function switch to the
position.
2. Insert the black test lead banana
plug into the negative
COM
jack.
3. Insert the red test lead banana
plug into the positive jack.
4. Press the
MODE
key to switch the
continuity functions.
5. If the resistance is less than
approximately
50Ω
, the audible
signal will sound. If the circuit is
open, the display will indicate
“OL”
.
1. Set the function switch to the
position.
2. Insert the black test lead banana
plug into the negative
COM
jack.
3. Insert the red test lead banana
plug into the positive
Ω
Jack.
4. Read the resistance in the display.
4.5. Resistance Measurements
To avoid electric shock, disconnect power to the
unit under test and discharge all capacitors
before taking any resistance measurements.
Remove the batteries and unplug the line cords.
WARNING:
To avoid electric shock, disconnect
power to the unit under test and discharge all
capacitors before taking any resistance
measurements. Remove the batteries and
unplug the line cords.
4.6. Continuity Check
MAX 10A
MAX 10A
13