    A. Gas Appliances, electrical and manual compo-
nents, glass panels, all sealants or adhesives and op-
tional accessories 

(exclusive of CFM Corporation supplied 

decorative logs which are covered by a separate warranty 
under paragraph B below):
    Within two years from the date of manufacture of the gas 
appliance, CFM Corporation will repair, or replace (at our op-
tion) a defective part without charge.

   B.  Cement or ceramic fiber log components:

Within two years from the date of manufacture of the gas 
appliance, CFM Corporation will replace a defective part 
without charge.  Within years three through twenty from the 
date of manufacture of the gas appliance, CFM Corporation 
will provide a replacement for a defective part to the hom-
eowner, but assumes no liability for incurred labor cost.
    The foregoing  warranties gives you specific legal rights 
and you may also have other rights which vary from state to 
state.  Some states do not allow limitations on how long an 
implied warranty may last, so the limitation specified above 
on the duration of any implied warranty prescribed by law 
may not apply to you.  Similarly, some states do not permit 
the exclusion or limitation of incidental or consequential 
damages, so the above exclusion of such damages may not 
apply to you.
    In order to obtain performance of any of the above war-
ranty obligations, write to CFM Corporation at this address:
  CFM Corporation
  410 Admiral Blvd
  Mississauga, Ontario Canada L5T 2N6
  Attention: Manager of Warranty Services

   
  Since local building requirements may vary greatly 
throughout the country, users of CFM Corporation products 
should determine in advance whether there are any building 
code restrictions on the use of a specified product.
CFM CORPORATION MAKES NO REPRESENTATION OR 
WARRANTY REGARDING, AND SHALL NOT BE RESPON-
SIBLE FOR, ANY BUILDING CODE COMPLIANCE.

 

The foregoing warranties give you specific legal rights and you may 
also have other rights which vary from state to state.

  CFM Corporation extends the warranties specified in 
paragraphs A and B below with respect to its Vermont 
Castings Decorative Gas Appliances (the “Gas Appliance”), 
including CFM Corporation supplied accessories and 
components referred to in those paragraphs, subject to the 
following conditions and limitations:
    (1) These warranties are extended only to the Gas Ap-
pliance installed in the continental United States, including 
Alaska, and Canada; only if and so long as the accordance 
with the installation and operating instructions furnished 
therewith; and only if and so long as Gas Appliance is not 
removed from its original installation.
    (2). These warranties are limited to only the component 
parts manufactured and supplied by CFM Corporation. The 
use of components manufactured by others with the Gas Ap-
pliance (except for a listed Type B venting system as defined 
in the installation instructions) could create serious safety 
hazard, may result in the denial of  certification by recog-
nized national safety agencies, and could be in violation of 
local building codes.
   (3). The Gas Appliance must be operated at all times in 
accordance with the operating instruction furnished there-
with. The Gas Appliance is designed to burn either natural or 
propane gas only.  Burning conventional fireplace fuels such 
as wood, coal, or any other solid fuel will cause damage to 
the Gas Appliance, will produce excessive temperatures and 
will result in a fire hazard.
    (4). These warranties are limited to repair, replacement or 
furnishing a replacement for sale, as specified in Paragraphs 
A and B, for a part found to CFM Corporation satisfaction, 
after examination, to be defective in materials or workman-
ship under normal conditions, use and service.
    (5).  All obligations with respect to these warranties may 
be fully discharged by CFM Corporation refunding the whole-
sale price of a defective part.
    (6)  Except as otherwise expressly specified in Para-
graphs A and B. NONE OF THESE WARRANTIES COVER, 
AND CFM CORPORATION SHALL NOT BE RESPONSI-
BLE FOR, ANY CONSTRUCTION, INSTALLATION, LABOR, 
TRANSPORTATION OR OTHER COSTS OR EXPENSES 
ARISING FROM A DEFECTIVE PART, ITS REPAIR OR 
REPLACEMENT OR OTHERWISE, NOR SHALL CFM 
CORPORATION IN ANY EVENT BE RESPONSIBLE FOR 
ANY INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAM-
AGES.  EXCEPT TO THE EXTENT PROVIDED BY LAW, 
THERE ARE NO IMPLIED WARRANTIES WITH RESPECT 
TO THE GAS APPLIANCE, ITS COMPONENTS AND AC-
CESSORIES (INCLUDING IMPLIED WARRANTIES OF 

LIMITED 2/20 YEAR WARRANTY

For Majestic Fireplaces Decorative Gas Appliances

Содержание VL18

Страница 1: ...rpora tion or company experienced in the installa tion repair and servicing of this type of gas appliance Do not modify alter or tamper with any part of this heater control or logs Do not store or use...

Страница 2: ...a sniffer Never test by using an open ame The area around the gas logset must be free of all combus tible materials especially gasoline or other highly ammable vapor producing liquids Due to high temp...

Страница 3: ...n USA installations must be in accordance with the current ANSI Z223 1 NFPA 54 and or local codes having jurisdiction In Canada please consult provincial and or local authorities having jurisdiction f...

Страница 4: ...cal codes If unvented room heaters are not permit ted the replace vent damper must be locked at the minimum vent area required by local codes or by the National Fuel Gas Code ANSI Z223 1 NFPA 54 lates...

Страница 5: ...openings If your home meets all of the above criteria you must provide additional fresh air for the appliance as detailed on Page 6 If your home does not meet the above criteria follow the procedure b...

Страница 6: ...r used by appliances In this example the maximum BTU hour that the space can support is less than the total used by the applianc es The space is considered to be Con ned Space Additional air must be p...

Страница 7: ...the manufacturer from outside the replace as marked by the manufacturer An ON OFF valve should be placed within easy reach of the appliance After the gas supply is installed reinstall the insulation r...

Страница 8: ...inside the re place locate the damper locking bracket on the left side of combustion dome Fig 4 Align the two slots on either side of the cutout on the damper stop with the two small holes on the ang...

Страница 9: ...e appliance to terminate at the right hand side for connection to the inlet of the appliance Connect the appliance to the gas line using ttings and aluminum tubing provided Close the valve knob on the...

Страница 10: ...stalled there must be noncombustible material from the top front opening of the replace to a height of 6 and the full width of the replace A combustible at mantel shelf and breastplate may be installe...

Страница 11: ...0 Locator Pin Fig 7 VL18 log placement LG102 VL21 logset 3 31 99 modified burner grate 4 3 00 djt Locator Pins Grate LG102 Locator Pin Locator Pin Fig 8 VL21 log placement LG104 VL24 logset 4 1 99 mod...

Страница 12: ...d the heater area for gas Be sure to smell next to the oor because some gas is heavier than air and will settle on the oor WHAT TO DO IF YOU SMELL GAS Do not try to light any replace Do not touch any...

Страница 13: ...ury do not touch hot surfaces when the appliance is operating Touch only the valve control knob Avoid contact with the grate feet or prongs or any other part which may be very hot Always ensure that t...

Страница 14: ...4 1 99 changed valve 4 14 00 djt HI OFF PIL OT LO 7 9 Approx 6 8 Ap prox Fig 13 Typical ame patterns P101 Pilot w flame 3 26 99 djt LOW HIGH PILOT OFF Knob Shown in Pilot Position Flame Piezo Ignitor...

Страница 15: ...allow ing gas to ow D No gas supply to the replace A Defective thermocouple B Thermocouple tting not tight in valve C Weak pilot ame D Defective valve E Not enough oxygen in the room DANGER A Plugged...

Страница 16: ...ree Gas Logs Ref Description VL18 VL21 VL24 1 Complete Log Set 2242104 3141108 2240104 1a Top Side Logs 2 7398129 7398129 7398129 1b Top Center Log 7398128 7398128 2 1c Rear Bottom Log 2242106 3141110...

Страница 17: ...ef Description VL18 VL21 VL24 6b Burner Assembly LP 20002632 20002629 20002575 Copreci Valve 7 Nut 15mm 7511168 7511168 7511168 8 Valve Control Knob Extension 7536237 7536237 7536237 9 Knob 7536250 75...

Страница 18: ...information beyond what your dealer can furnish contact CFM Corporation 410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 Attention Technical Service Accessory Description Required to protect wall a...

Страница 19: ...arranties speci ed in paragraphs A and B below with respect to its Vermont Castings Decorative Gas Appliances the Gas Appliance including CFM Corporation supplied accessories and components referred t...

Страница 20: ...CFM Corporation 410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 800 668 5323 www cfmcorp com CFM Corporation...

Отзывы: