W A R N I N G 

If the information in this manual is not followed exactly, a fire or explosion may result, causing property 

damage, injury, or loss of life. 

W A R N I N G 

CARBON MONOXIDE POISONING MAY LEAD TO DEATH

When used without fresh air, vent-free log sets may give off carbon monoxide, an odorless, poisonous gas.  
Some people - pregnant women, people with heart or lung disease, anemia, or persons under the influence of alcohol, and 
persons at high altitudes are more affected by carbon monoxide than others. 
Early signs of carbon monoxide poisoning resemble the flu - headache, dizziness, and/or nausea. If you have these signs, the 
heater may not be installed or working properly. 

GET FRESH AIR AT ONCE!

 Have the heater serviced before using it again. 

ATTENTION

Installation and service must be performed by 

a qualified agency, individual, firm, corpora-

tion, or company, experienced in the installa-

tion, repair, and servicing of this type of gas 

appliance. Do not modify, alter or tamper with 

any part of this heater, control, or  logs.

— 

Do not store or use gasoline or other flamma-
ble vapors and liquids in the vicinity of this or 
any other appliance.

— 

WHAT TO DO IF YOU SMELL GAS

• 

Do not try to light any appliance.

• 

Do not touch any electrical switch; do not 
use any phone in your building.

• 

Immediately call your gas supplier from a 
neighbor’s phone. Follow the gas suppli-
er’s instructions.

• 

If you cannot reach your gas supplier, call 
the fire department.

This appliance may be installed in an after-
market, permanently located, manufactured 
(mobile) home, where not prohibited by local 
codes.
This appliance is only for use with the type 
of gas indicated on the rating plate. This ap-
pliance is not convertible for use with other 
gases.

INSTALLER PLEASE NOTE:

DO NOT begin installation of this gas logset 

until all instructions have been read and 

understood. 

INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

Tested and listed to 

ANSI Z21.11.2b-2004, Unvented Heaters, and 

Z21.60b-2004; CGA 2.26b-2004 

Decorative Gas Appliances for 

Installation inSolid-Fuel Burning Fireplaces.

Содержание VL18

Страница 1: ...rpora tion or company experienced in the installa tion repair and servicing of this type of gas appliance Do not modify alter or tamper with any part of this heater control or logs Do not store or use...

Страница 2: ...a sniffer Never test by using an open ame The area around the gas logset must be free of all combus tible materials especially gasoline or other highly ammable vapor producing liquids Due to high temp...

Страница 3: ...n USA installations must be in accordance with the current ANSI Z223 1 NFPA 54 and or local codes having jurisdiction In Canada please consult provincial and or local authorities having jurisdiction f...

Страница 4: ...cal codes If unvented room heaters are not permit ted the replace vent damper must be locked at the minimum vent area required by local codes or by the National Fuel Gas Code ANSI Z223 1 NFPA 54 lates...

Страница 5: ...openings If your home meets all of the above criteria you must provide additional fresh air for the appliance as detailed on Page 6 If your home does not meet the above criteria follow the procedure b...

Страница 6: ...r used by appliances In this example the maximum BTU hour that the space can support is less than the total used by the applianc es The space is considered to be Con ned Space Additional air must be p...

Страница 7: ...the manufacturer from outside the replace as marked by the manufacturer An ON OFF valve should be placed within easy reach of the appliance After the gas supply is installed reinstall the insulation r...

Страница 8: ...inside the re place locate the damper locking bracket on the left side of combustion dome Fig 4 Align the two slots on either side of the cutout on the damper stop with the two small holes on the ang...

Страница 9: ...e appliance to terminate at the right hand side for connection to the inlet of the appliance Connect the appliance to the gas line using ttings and aluminum tubing provided Close the valve knob on the...

Страница 10: ...stalled there must be noncombustible material from the top front opening of the replace to a height of 6 and the full width of the replace A combustible at mantel shelf and breastplate may be installe...

Страница 11: ...0 Locator Pin Fig 7 VL18 log placement LG102 VL21 logset 3 31 99 modified burner grate 4 3 00 djt Locator Pins Grate LG102 Locator Pin Locator Pin Fig 8 VL21 log placement LG104 VL24 logset 4 1 99 mod...

Страница 12: ...d the heater area for gas Be sure to smell next to the oor because some gas is heavier than air and will settle on the oor WHAT TO DO IF YOU SMELL GAS Do not try to light any replace Do not touch any...

Страница 13: ...ury do not touch hot surfaces when the appliance is operating Touch only the valve control knob Avoid contact with the grate feet or prongs or any other part which may be very hot Always ensure that t...

Страница 14: ...4 1 99 changed valve 4 14 00 djt HI OFF PIL OT LO 7 9 Approx 6 8 Ap prox Fig 13 Typical ame patterns P101 Pilot w flame 3 26 99 djt LOW HIGH PILOT OFF Knob Shown in Pilot Position Flame Piezo Ignitor...

Страница 15: ...allow ing gas to ow D No gas supply to the replace A Defective thermocouple B Thermocouple tting not tight in valve C Weak pilot ame D Defective valve E Not enough oxygen in the room DANGER A Plugged...

Страница 16: ...ree Gas Logs Ref Description VL18 VL21 VL24 1 Complete Log Set 2242104 3141108 2240104 1a Top Side Logs 2 7398129 7398129 7398129 1b Top Center Log 7398128 7398128 2 1c Rear Bottom Log 2242106 3141110...

Страница 17: ...ef Description VL18 VL21 VL24 6b Burner Assembly LP 20002632 20002629 20002575 Copreci Valve 7 Nut 15mm 7511168 7511168 7511168 8 Valve Control Knob Extension 7536237 7536237 7536237 9 Knob 7536250 75...

Страница 18: ...information beyond what your dealer can furnish contact CFM Corporation 410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 Attention Technical Service Accessory Description Required to protect wall a...

Страница 19: ...arranties speci ed in paragraphs A and B below with respect to its Vermont Castings Decorative Gas Appliances the Gas Appliance including CFM Corporation supplied accessories and components referred t...

Страница 20: ...CFM Corporation 410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 800 668 5323 www cfmcorp com CFM Corporation...

Отзывы: