7
71D0531
VF/VFR Vent-Free Fireboxes
HEARTH DIMENSIONS and FIREBOx LOCATION
A
B
C
D
E
FP2901
hearth dims
Ref.
VF/VFR32C
VF/VFR36C
VF/VFR42C
A
9
M\,
"
34"
40"
B
13
Z\v
"
15
C\v
"
15
C\v
"
C
3
C\,
"
7
C\,
"
33
C\,
"
D
1
M\,
"
1
M\,
"
1
M\,
"
E
18"
17
B\,
"
17
B\,
"
Figure 2 -
Minimum Hearth Dimensions
LOCATION OF FIREBOx
Carefully select the best location for installation of your
vent-free firebox. The following factors should be taken
into consideration:
•
Clearance to side wall, ceiling, woodwork and windows.
See “Clearances/Height Requirements on page 8.
Minimum clearances to combustibles
must be main-
tained.
•
Location must not be affected by drafts caused by
kitchen exhaust fans, ceiling fans, return air registers
for forced air furnaces / air conditioners, windows or
doors.
•
Installation must provide adequate ventilation and com-
bustion air.
•
DO NOT INSTALL THIS FIREBOx IN A BEDROOM
OR BATHROOM.
•
Location should be out of high traffic or windy or drafty
areas.
•
DO NOT INSTALL WHERE CURTAINS, FURNITURE,
CLOTHING OR OTHER FLAMMABLE OBJECTS ARE
LESS THAN 42" FROM FRONT OF HEATER.
•
Never obstruct the front opening of the vent-free firebox
or restrict the flow of combustion and ventilation air.
•
Minimize modifications to existing construction. Refer
to
Figure 3
below for location suggestions.
•
Do not install in the vicinity where gasoline or other
flammable liquids may be stored. The vent-free firebox
must be kept clear and free from these combustible
materials.
FP2440
fireplace locations
Figure 3 -
Location of Firebox