Majestic VF Скачать руководство пользователя страница 3

3

71D0531

VF/VFR Vent-Free Fireboxes

13. Correct installation of the ceramic fiber logs, proper 

location of the heater, and annual cleaning are neces-

sary to avoid potential problems with sooting. Sooting, 

resulting from improper installation or operation, can 

settle on surfaces outside the fireplace. See log place-

ment instructions for proper installation.

14. Avoid any drafts that alter burner flame patterns. Do not 

allow fans to blow directly into fireplace. Do not place 

a blower inside burn area of firebox. Ceiling fans may 

create drafts that alter burner flame patterns. Sooting 

and improper burning will occur.

15. 

CAUTION:

 Candles, incense, oil lamps, etc. produce 

combustion byproducts including soot. Vent-free appli-

ances will not filter or clean soot produced by these 

types of products. In addition, the smoke and/or aro-

matics (scents) may be reburnt in the vent-free appli-

ance which can produce odors. It is recommended to 

minimize the use of candles, incense, etc. while the 

vent-free appliance is in operation. 

16. An unvented gas-fired heater uses air (oxygen) from 

the room in which it is installed. Provisions for adequate 

combustion and ventilation air must be provided. See 

installation guidelines. 

17. Keep  room  area  clear  and  free  from  combustible 

materials, gasoline and other flammable vapors and 

liquids.

18. Unvented gas heaters are a supplemental zone heater. 

They are not intended to be a primary heating appli-

ance.

19. Unvented  gas  heaters  emit  moisture  into  the  living 

area.  In  most  homes  of  average  construction,  this 

does  not  pose  a  problem.  In  houses  of  extremely 

tight construction, additional mechanical ventilation is 

recommended. 

0. During manufacturing, fabricating and shipping, various 

components of this appliance are treated with certain 

oils, films or bonding agents. These chemicals are not 

harmful but may produce annoying smoke and smells 

as they are burned off during the initial operation of the 

appliance; possibly causing headaches, or eye or lung 

irritation. This is a normal and temporary occurrence.

IMpORTANT SAFETY INFORMATION

8.  

CARBON  MONOxIDE  pOISONING:

  Early  signs  of 

carbon monoxide poisoning are similar to the flu with 

headaches, dizziness and/or nausea. If you have these 

signs, obtain fresh air immediately. Have the heater 

serviced as it may not be operating properly.

9.  The installation must conform with local codes or, in 

the absence of local codes, with the National Fuel Gas 

Code, ANSI Z3.l/NFPA54.

10. This unit complies with ANSI Z1.91 ventless firebox 

enclosures  for  gas-fired  unvented  decorative  room 

heaters.

11.  Do not install the unvented heater in a bathroom.
1. Do not install the unvented heater in a bedroom unless 

the  maximum  input  rating  is  equal  to  or  less  than 

10,000 Btu/hr.

Continued on page 4

INSTALLER

Please leave these instructions with the appliance.

OWNER

Please retain these instructions for future reference.

W

ARNING

• 

Any change to this heater or its controls can be dangerous.

  Improper installation or use of the heater can cause serious injury or death from 

fire, burns, explosion or carbon monoxide poisoning.

  Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter 

burner flame patterns.

  Do  not  use  a  blower  insert,  heat  exchanger  insert  or  other  accessory,  not 

approved for use with this heater where applicable.

1.  Due  to  high  temperatures,  the  firebox  should  be 

located out of traffic and away from furniture and 

draperies.

.  Children and adults should be alerted to the hazard 

of high surface temperature and should stay away 

to avoid burns or clothing ignition.

3.  Young children should be carefully supervised when 

they are in the same room with the firebox.

4.  Do not place clothing or other flammable material 

near the fireplace when the firebox is in use.

5.  Any safety screen or guard removed for servicing, 

must be replaced prior to operating a heater within 

the firebox. 

6.  Installation and repair should be done by a qualified 

service person.

7.   To prevent malfunction and/or sooting, an unvented 

gas heater/firebox should be cleaned at least annu-

ally by a professional service person. More frequent 

cleaning may be required due to excessive lint from 

carpeting, etc. It is imperative that control compart-

ments, burners and circulating air passageways be 

kept clean.

Содержание VF

Страница 1: ...plier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNINGS For...

Страница 2: ...ctions may result in a possible fire hazard and will void the warranty Important Safety Information 3 General Installation Information 5 Before You Start 5 What You Will Need for Installation 5 Firebo...

Страница 3: ...PORTANT SAFETY INFORMATION 8 CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning are similar to the flu with headaches dizziness and or nausea If you have these signs obtain fresh air i...

Страница 4: ...he control system and any gas control which has been under water 25 Never burn solid fuels in a fireplace where a unvented room heater is installed 26 Always have a fireplace screen in place when the...

Страница 5: ...Instructions 4 Five 5 sheet metal screws for canopy What you will need for installation TOOLS and BUILDING SUPPLIES Phillips screwdriver Square Framing materials Hammer Saw and or saber saw Tee joint...

Страница 6: ...6M 6 1 6QE 5 6QE N 21 6M E H J L G K Ref VF VFR32C VF VFR36C VF VFR42C A 37 41 47 B 32 36 42 C 16 18 18 D 29 32 38 E 18B 20B 20B F 23C 27C 33C G 13Z v 15C v 15C v H 18 17B 17B I 29M 34 40 J 7Z 9C v 9C...

Страница 7: ...ing fans return air registers for forced air furnaces air conditioners windows or doors Installation must provide adequate ventilation and com bustion air DO NOT INSTALL THIS FIREBOX IN A BEDROOM OR B...

Страница 8: ...wall MINIMUM CLEARANCES 9 Minimum 42 Minimum 9 Minimum FP2687 minimum clearances FP2687 Figure 4 Clearance and Height Requirements 4 Mantel clearances The canopy supplied with the unit must be instal...

Страница 9: ...tion noncombustible material includes but is not limited to stone brick and mortar Noncombustibles are safe to overlay the black painted metal face including radiant plates and do not pose a fire haza...

Страница 10: ...igure 11 Installing Canopy FP2451 install canopy Screws Canopy FP2451 WARNING The firebox canopy must not be modified or replaced with a canopy that may be provided with the unvented decorative room h...

Страница 11: ...rough trap to the heater controls and burners Failure to do so could prevent the heater from operating reliably Consult appli cable codes An external regulator must be used on all propane L P G heater...

Страница 12: ...rom any ap pliance vent terminal 6 Avoid extremely long runs and numerous turns in the duct leading from the fireplace to the combustion air assembly These conditions increase the resistance to the fr...

Страница 13: ...OA start collar 8 08 Figure 16 Attach Outside Air Starting Collar and Insulation Ring to Left Side of Fireplace Insulation Ring AK 4 Starting Collar Sheet Meal Screws Left Side of Fireplace Shorter En...

Страница 14: ...Note If the wall covering is brick or stone use appropriate masonry fasteners If necessary splice the duct Use a model 403 duct connector to splice duct sections Install model 403 duct connector 1 Pus...

Страница 15: ...be installed in place of the factory installed black louvers Refer to installation instructions provided with the brass or pewter louvers OPTIONAL Trim Optional trim kits can be used with unit when in...

Страница 16: ...1 Wide Brass Canopy 1 BRC32 BRC36 BRC42 4 Brass Louver 1 L32BR L36BR L42BR 4 Pewter Louver 1 L32PW L36PW L36PW 5 Blower w Rheostat 1 BLOTMC BLOTMC BLOTMC 6 Brass Trim Curved Design 1 BRTK32C BRTK36C B...

Страница 17: ...17 71D0531 VF VFR Vent Free Fireboxes...

Страница 18: ...71D0531 18 VF VFR Vent Free Fireboxes...

Страница 19: ...ons The Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox...

Страница 20: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...

Отзывы: