VF/VFR Vent-Free Fireboxes

OpTIONAL EqUIpMENT 

FORCED AIR kIT 

(BLOTMC)

If you are installing the forced air kit on VF-TB or VF-R models, see the installation instructions 

provided with the kit for electrical wiring requirements, or the blower installation section.  The 

firebox must be connected to main power supply at time of firebox installation. The blower 

must be installed prior to the installation of the vent-free heater. The electrical connections 

must be made before the firebox is framed and enclosed in the finished walls.

BRASS OR pEWTER LOUVERS AND FILIGREE

 

Optional brass or pewter louver kits may be installed in place of the factory installed black 

louvers. Refer to installation instructions provided with the brass or pewter louvers.

OpTIONAL TRIM

Optional trim kits can be used with unit when installed as a free standing fireplace with 

wood surround.

FIREBRICk

Optional firebrick kits can be installed. See installation instructions provided with kit.

OpTIONAL WIDE CANOpY

 

The optional wide canopy can be installed. See installation instructions provided with kit.

W

ARNING

Electrical  connections  should  only  be 

performed by a qualified, licensed electrician, 

main power must be off when connecting to 

main electrical power supply or performing 

service.
The  blower  when  installed,  must  be 

electrically  grounded  in  accordance  with 

local codes or in the absence of local codes, 

with the National Electrical Code ANSI/NFpA 

70.

Содержание VF

Страница 1: ...plier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNINGS For...

Страница 2: ...ctions may result in a possible fire hazard and will void the warranty Important Safety Information 3 General Installation Information 5 Before You Start 5 What You Will Need for Installation 5 Firebo...

Страница 3: ...PORTANT SAFETY INFORMATION 8 CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning are similar to the flu with headaches dizziness and or nausea If you have these signs obtain fresh air i...

Страница 4: ...he control system and any gas control which has been under water 25 Never burn solid fuels in a fireplace where a unvented room heater is installed 26 Always have a fireplace screen in place when the...

Страница 5: ...Instructions 4 Five 5 sheet metal screws for canopy What you will need for installation TOOLS and BUILDING SUPPLIES Phillips screwdriver Square Framing materials Hammer Saw and or saber saw Tee joint...

Страница 6: ...6M 6 1 6QE 5 6QE N 21 6M E H J L G K Ref VF VFR32C VF VFR36C VF VFR42C A 37 41 47 B 32 36 42 C 16 18 18 D 29 32 38 E 18B 20B 20B F 23C 27C 33C G 13Z v 15C v 15C v H 18 17B 17B I 29M 34 40 J 7Z 9C v 9C...

Страница 7: ...ing fans return air registers for forced air furnaces air conditioners windows or doors Installation must provide adequate ventilation and com bustion air DO NOT INSTALL THIS FIREBOX IN A BEDROOM OR B...

Страница 8: ...wall MINIMUM CLEARANCES 9 Minimum 42 Minimum 9 Minimum FP2687 minimum clearances FP2687 Figure 4 Clearance and Height Requirements 4 Mantel clearances The canopy supplied with the unit must be instal...

Страница 9: ...tion noncombustible material includes but is not limited to stone brick and mortar Noncombustibles are safe to overlay the black painted metal face including radiant plates and do not pose a fire haza...

Страница 10: ...igure 11 Installing Canopy FP2451 install canopy Screws Canopy FP2451 WARNING The firebox canopy must not be modified or replaced with a canopy that may be provided with the unvented decorative room h...

Страница 11: ...rough trap to the heater controls and burners Failure to do so could prevent the heater from operating reliably Consult appli cable codes An external regulator must be used on all propane L P G heater...

Страница 12: ...rom any ap pliance vent terminal 6 Avoid extremely long runs and numerous turns in the duct leading from the fireplace to the combustion air assembly These conditions increase the resistance to the fr...

Страница 13: ...OA start collar 8 08 Figure 16 Attach Outside Air Starting Collar and Insulation Ring to Left Side of Fireplace Insulation Ring AK 4 Starting Collar Sheet Meal Screws Left Side of Fireplace Shorter En...

Страница 14: ...Note If the wall covering is brick or stone use appropriate masonry fasteners If necessary splice the duct Use a model 403 duct connector to splice duct sections Install model 403 duct connector 1 Pus...

Страница 15: ...be installed in place of the factory installed black louvers Refer to installation instructions provided with the brass or pewter louvers OPTIONAL Trim Optional trim kits can be used with unit when in...

Страница 16: ...1 Wide Brass Canopy 1 BRC32 BRC36 BRC42 4 Brass Louver 1 L32BR L36BR L42BR 4 Pewter Louver 1 L32PW L36PW L36PW 5 Blower w Rheostat 1 BLOTMC BLOTMC BLOTMC 6 Brass Trim Curved Design 1 BRTK32C BRTK36C B...

Страница 17: ...17 71D0531 VF VFR Vent Free Fireboxes...

Страница 18: ...71D0531 18 VF VFR Vent Free Fireboxes...

Страница 19: ...ons The Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox...

Страница 20: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...

Отзывы: