BV4536, BV5142 Natural Vent Gas Fireplace
45”
Min.
A
A
E Min.
E Min.
A
412001
VB4536 5142 framing dims
1/09
A
B Min.
C Min.
D Min.
FIREPLACE FRAMING
Firebox framing can be built before or after the appliance is set in place. Construct firebox framing fol-
lowing
Figure 3
and the chart below for your specific installation requirements. Refer to
Page 6, Figures
1 & 2
for firebox dimensions. The framing headers may rest on the top of the firebox standoffs.
The firebox may be installed directly on a combustible floor or raised on a platform of an appropriate
height. When the firebox is installed directly on carpeting, tile or other combustible material, other than
wood flooring, the firebox shall be installed on a metal or wood panel extending the full width and depth
of the enclosure.
FIREPLACE FRAMING
Do not fill spaces around firebox with
insulation or other materials. This
could cause a fire.
W
ARNING
Figure 3 -
Framing Dimensions
BV4536
BV5142
A
45
C\,
”
51
C\,
”
B
80
C\v
”
86
C\v
”
C
57
Z\v
”
60
C\,
”
D
40
C\,
”
43
C\,
”
E
23
B\,
”
23
B\,
”