41D2001

30

BV4536, BV5142 Natural Vent Gas Fireplace

TROUBLESHOOTING

STANDING PILOT IGNITION

SYMPTOM

1.  Spark igniter 

will not light pi-
lot after repeat-
ed triggering of 
piezo.

2.  Pilot will not 

stay lit after 
carefully fol-
lowing lighting 
instructions.

3.  Pilot burning, 

valve knob 
tuned to “ON”, 
switch is turned 
to “ON” or “RS”, 
but burner will 
not ignite.

4.  Frequent pilot 

outage prob-
lem.

5.  The pilot and 

main burner 
extinguish while 
in operation.

POSSIBLE CAUSE

A.  Wire disonnected.

B.  Defective igniter.

C. No gas or low gas 

pressure.

D. No Propane/LPG in 

tank.

A.  Defective thermocou-

ple.

B.  Defective valve.

A.  Defective switch, wall 

switch, remote control 
or wire.

B.  Pilot flame too small.

C. Defective or malfunc-

tioning thermopile.

D. Defective valve.

A.  Pilot flame may be too 

high or too low, caus-
ing pilot safety to drop 
out.

A.  Inner vent pipe leaking 

exhaust gases back 
into system.

B.  Horizontal vent improp-

erly pitched.

C. Improper vent cap 

installation.

ACTION

A.  Open door and check to make sure wire is connected to 

igniter.

B.  Check for spark at electrode and pilot. If no spark and elec-

trode wire is properly connected, replace pilot assembly.

C. Check remote/manual shut-off valve from fireplace. Low 

pressure can be caused by bent lines, restricted lines, low 
pressure line pressure. Consult with plumber or gas supplier.

D. Check Propane/LPG tank. Refill tank.

A.  Check that thermocouple flame impinges on thermocouple. 

Clean and/or adjust pilot for maximum flame impingement. 
Ensure that the thermocouple connection at the gas valve is 
fully inserted and tight.

  Disconnect the thermocouple from the valve, place one mil-

livolt lead wire on the tip of the thermocouple and the other 
meter lead wire on the thermocouple copper lead. Start the 
pilot and hold the valve knob in. If the millivolt reading is less 
than 15m V, replace pilot assembly.

B.  If thermocouple is producing more than 15m V, replace faulty 

valve.

A.  Check switch and wire for proper connection. Place jumper 

wires across terminals of switch. If burner comes on, replace 
defective switch. If the switch is OK, repeat the same proce-
dure on remote control. If burner comes on, replace remote 
control. Place jumper wire across wire at gas valves (termi-
nals marked TH and TP/TH). If burner comes on, wires are 
faulty or connections are bad. Replace wire.

B.  If pilot flame is not close enough to the thermopile, adjust 

pilot flame.

C. Check thermopile wire connections to make sure all are tight 

and that the thermopile is fully inserted into pilot assembly. 
Check thermopile with a millivolt meter. Connect leads to TP 
and TP/TH terminals on the control valve. If meter reading is 
below 325m V, replace pilot assembly.

D. Turn valve knob to “ON” and switch to “ON”. Take a reading 

at the thermopile leads (TP & TP/TH) on the valve. If the me-
ter reads greater than 175m V and the burner does not light, 
replace defective valve.

A.  Clean and adjust the pilot flame for maximum flame impinge-

ment on thermocouple.

A.  Check for flue product leak. Replace defective pipe section.

B.  Check horizontal-vent piping is running upward 1/4” per foot. 

Do not run the pipe level or downward.

C. Check for proper installation and freedom from debris or 

blockage.

Содержание Super B-Vent Series BV4536

Страница 1: ...ncy or the gas supplier WARNING Improper installation adjustment alteration services or maintenance can cause injury or property damage Refer to this man ual For assistance or additional information c...

Страница 2: ...Up 11 Vertical Venting w Elbows 12 Install Vent Components 12 Firestop Installation 13 Vertical Termination 14 Outside Air Kit 15 Fireplace Installation 16 Check Gas Type 16 Installing Gas Piping to...

Страница 3: ...To prevent performance problems do not use propane LP fuel tank of less than 100 lbs capacity 3 If you smell gas shut off gas supply do not try to light any appliance do not touch any electrical swit...

Страница 4: ...same atmospheric pressure zone as the combustion air inlet to the appliance 23 For Massachusetts Residents Only This product must be installed by a licensed plumber or gas fitter when installed withi...

Страница 5: ...is found Do not install any unit with damaged incomplete or substitute parts Check your packing list to verify that all listed parts have been received You should have the following Fireplace Firebox...

Страница 6: ...as Fireplace FIREPLACE DIMENSIONS Figure 1 BV4536 Dimensions 45 36 2256O 3356O 2356O 11 6M 41 26 756O 4456 2 6 756M 412001 BV4536 dims 51 42 2556O 3956O 2356O 11 6M 41 26 756O 4456 2 6 756M 412001 BV5...

Страница 7: ...eaders may rest on the top of the firebox standoffs The firebox may be installed directly on a combustible floor or raised on a platform of an appropriate height When the firebox is installed directly...

Страница 8: ...t edition and Local Building Codes for specific installation requirements WALL and CEILING CLEARANCE REQUIREMENTS Ensure that minimum clearances shown in Figure 4 are maintained Left and right clearan...

Страница 9: ...e appliance is a zero clearance fireplace with ribs spacers defining the minimum space to the sheet metal outer shell Combustibles may be placed up against these spacers Do NOT place combustibles i e...

Страница 10: ...ntified in this manual NOTE Any remote wiring i e remote control and wall switch must be done prior to final finishing to avoid costly reconstruction 0 FINISHING MATL Combustible Finishing Material Hi...

Страница 11: ...r must follow these safety rules Wear gloves and safety glasses for protection Use extreme caution when using ladders or when on rooftops Be aware of electrical wiring locations in walls and ceilings...

Страница 12: ...nents Be certain that each section is locked properly 3 Where necessary add support brackets Figure 9 Incline runs must be supported every 3 Vertical runs must be sup ported every 8 using wall straps...

Страница 13: ...ing using the center point 5 Frame the hole with framing lumber the same size as the ceiling joists Position firestop If attic is above mount firestop on top of framing Figure 10 If room is above moun...

Страница 14: ...10 12 to 11 12 3 3 Over 11 12 to 12 12 4 Over 12 12 to 14 12 5 Over 14 12 to 16 12 6 Over 16 12 to 18 12 7 Over 18 12 to 20 12 7 6 Over 20 12 to 21 12 8 Figure 12 Minimum Vent Height for Various Roof...

Страница 15: ...product into the living area OUTSIDE AIR KIT INSTALLATION 1 Attach aluminum flexible hose to outside air door on the appliance securing it with a spring clamp 2 Cut a hole through outside wall place o...

Страница 16: ...rner system regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 14 Pointing the vent down protects it from freezing rain or sleet WARNING A qualified...

Страница 17: ...the gas to the fireplace Check your building codes for any special requirements for locating equipment shut off valve to fireplaces Apply pipe joint sealant lightly to male threads This will pre vent...

Страница 18: ...from the gas meter to the fireplace for leaks Use a solution of 50 50 water and soap or a gas sniffer 4 To adjust flame height turn HI LO knob to HI to get maximum pressure to burner Turn HI LO knob t...

Страница 19: ...only be performed by a qualified licensed electrician Main power must be off when connecting to main electrical power supply or performing service All wiring shall be in compliance with all local city...

Страница 20: ...ver at junction box for your wall switch Pilot must be lit and the valve control knob turned to the ON position Meter leads must be con nected to the TP and TH TP terminals on the control valve Turn R...

Страница 21: ...off any gaps at the top and sides between the fireplace and the finishing to prevent cold air leaks Refer to Page 10 Figure 6 for allowable locations for combustible materials ROCK WOOL PLACEMENT Roc...

Страница 22: ...ve and discard the two 2 screws that secure the C Channel below the top opening of the fireplace 2 Attach bottom rail to unit with two 2 sheet metal screws Figure 20 3 Attach top rail to unit with two...

Страница 23: ...tion a naturally vented gas fireplace may not be installed in a bedroom or bathroom in the Commonwealth of Massachusetts WARNING Damper must be in open position when appliance main burner is operatin...

Страница 24: ...every second Subsequent lighting of the fireplace will not require this purging of air from the gas lines unless the gas valve has been shut off for a long period LIGHTING THE FIREPLACE You may notic...

Страница 25: ...the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it Call a qualified service technician...

Страница 26: ...nob pushed in push in and re lease the piezo ignitor button to light the pilot 9 Continue pushing the control knob in for a further 60 seconds to prevent the flame detector from shutting off the gas w...

Страница 27: ...ructions If you cannot reach your gas supplier call the fire department C Turn off all electric power to the appliance D Do not use this appliance if any part of it has been under water Immediately ca...

Страница 28: ...ation The pilot flame must always be present when the fireplace is in operation Figure 23 The pilot flame has three distinct flames one engulfing the thermopile one engulfing the thermo couple and the...

Страница 29: ...y glass that is chipped cracked or broken Replacement glass door assemblies nust be supplied by MHSC WARNING No substitute materials may be used WARNING Handle glass door with care to avoid striking o...

Страница 30: ...ocouple connection at the gas valve is fully inserted and tight Disconnect the thermocouple from the valve place one mil livolt lead wire on the tip of the thermocouple and the other meter lead wire o...

Страница 31: ...B Check electrical connections between module and pilot operator on gas control C Check for 24VAC across PV MVPV terminals If voltage is correct replace gas control If voltage is not correct replace m...

Страница 32: ...ir pressure A Blockage or restriction in venting ACTION A Install log set per instructions Inspect the injector and air intake area Make sure this area does not have any blockage from debris and clean...

Страница 33: ...9 Ref Description Qty BV4536 BV5142 1 Hi Temperature Limit Switch 1 41D0202 41D0202 2 Firebrick Walls T Brown 1 Set FB4536W9TB FB5142W9TB 2a Firebrick Center 1 41D2015 41D2016 2b Firebrick Left Side 1...

Страница 34: ...nversion Kits not shown Conversion NG to LP 1 SNPK3642 SNPK3642 Conversion LP to NG 1 SPNK3642 SPNK3642 Standing Pilot Millivolt Control Ref Description Qty BV4536NE BV4536PE BV5142NE BV5142PE 1 Gas V...