41D2001
23
BV4536, BV5142 Natural Vent Gas Fireplace
FINAL INSTALLATION
DAMPER OPERATION
1. When damper lever is all the way to the left and locked into position, the damper
system is closed.
Figure 22
2. Pull damper lever forward and unlock from closed position by swinging damper
lever to the right.
Figure 22
3. Swing damper lever to the right, forcing into the locked position, to open damper
system.
Figure 22
NOTE:
Remove damper instruction tag before operating the unit.
CLOSED
OPEN
FP2200
Damper operation
1/09
Damper Lever
Figure 22 -
Damper Operation
FP2200
NOTE
For Massachusetts Residents Only:
In-
stallation of this vented gas fireplace in the
Commonwealth of Massachusetts requires
the damper to be permanently removed or
welded into the fully open position. In addi-
tion, a naturally vented gas fireplace may
not be installed in a bedroom or bathroom in
the Commonwealth of Massachusetts.
W
ARNING
Damper must be in open position when appliance main burner is
operating. The damper system must be LOCKED into the OPEN
position during operation. If damper is not open, the appliance will
shut down at the pilot. Refer to Lighting Instructions if this occurs.
If damper system is not locked into the open position, the appli-
ance may cause some spillage into the living area before the tem-
perature switch can shut the pilot off.
Do not install a damper device to the appliance. Only use damper
device that comes with the unit.
HI-TEMPERATURE CUT OFF DISC
This unit is equipped with a shut off disc that helps prevent spillage due to a down draft. It also
helps prevent operation of the unit with damper closed. The Hi Temp switch is located on the
upper left corner of the fireplace opening.
DO NOT OPERATE THE FIREPLACE WITH THE
SWITCH BYPASSED.