![Majestic SB6000 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/majestic/sb6000/sb6000_installation-operation-and-maintanance-manual_4175687008.webp)
Survey the planned location for the fireplace for overhead plumbing or electrical wires, etc., that might complicate
the installation or endanger persons installing or cleaning the chimney. Avoid a location where the chimney
cap will be near abrupt changes in the roof shape, nearby wall or embankments, under or near trees or above
the roof of a single story wing of a two story building as shown by Figure 8. All these conditions can cause
turbulence or pressure conditions that can cause poor chimney draft and smoke spillage from the fireplace
opening. Elbows may be used to offset the chimney to avoid obstructions or to locate the chimney cap in a
preferred location. Refer to the sections of this manual pertaining to chimney offsets for instructions on proper
elbow use. Poor installation or location of the chimney cap and/or components can cause wind blown rain to
enter the chimney.
Be sure the selected location will allow a 17” square combustible material-free space for the chimney to pass
through. If the chimney is to pass through living or storage spaces, be sure there is adequate space to enclose
the chimney to avoid personal contact with, or damage to, the chimney. If the fireplace is to be installed on an
outside wall, the surrounding walls (chase) should be constructed and insulated as shown by Figure 6. Failure
to insulate the fireplace form outside temperatures will cause heat loss through and around the fireplace.
I
NSTALLATION
P
REPARATION
7
F
IGURE
6
53D9027