17
Majestic • MARQ42STIN Owner Manual • 2272-981 Rev. L • 12/20
Remote Control
Frequency:
Seasonally
By:
Homeowner
Tools needed:
Replacement batteries and remote con-
trol instructions.
• Locate remote control transmitter and receiver.
• Verify operation of remote. Refer to remote control
operation instructions for proper calibration and setup
procedure.
• Replace batteries as needed in remote transmitters.
• Place remote control out of reach of children.
If not using your fireplace for an extended period of time
(summer months, vacations/trips, etc), to prevent unin-
tended operation:
• Remove batteries from remote controls.
• Turn the ON/OFF/REMOTE switch on the control module
to OFF.
• Unplug 6 volt adapter plug on IPI models.
Venting and Termination Cap
Frequency:
Seasonally
By:
Homeowner
Tools needed:
Protective gloves and safety glasses.
• Inspect exposed venting and termination cap for block
-
age or obstruction such as plants, bird nests, leaves,
snow, debris, etc.
• Verify termination cap clearance to subsequent construc-
tion (building additions, decks, fences, or sheds).
• Inspect for corrosion or separation.
• Verify cauking and sealing of vent components and
termination cap remains intact.
CAUTION!
Handle fixed glass assembly with care.
Glass is breakable.
• Avoid striking, scratching or slamming glass
• Avoid abrasive cleaners
•
DO NOT
clean glass while it is hot
NOTICE!
Use only glass cleaner compatible with ce
-
ramic glass.
Other types of glass cleaner may damage
the glass surface when exposed to high temperatures.
•
Prepare a work area large enough to accommodate fixed
glass assembly and door frame by placing a drop cloth
on a flat, stable surface.
Note
: Fixed glass assembly and gasketing may have res
-
idue that can stain carpeting or floor surfaces.
•
Remove decorative barrier front from fireplace and set
aside on work surface.
• See appliance installation manual for instructions to
remove fixed glass assembly.
• Clean glass with a non-abrasive, non-ammonia based,
commercially available gas fireplace glass cleaner
.
- Light deposits: Use a soft cloth with soap and water
- Heavy deposits: Use commercial fireplace glass
cleaner (consult with your dealer)
• Carefully set fixed glass assembly in place on fireplace.
Hold glass in place with one hand and secure all glass
latches with the other hand.
• See appliance installation manual for instructions to
replace the fixed glass assembly.
• Inspect and operate all glass latches to ensure they move
freely and no obstructions are present.
• Reinstall decorative barrier front.
Gasket Seal and Glass Assembly Inspection
Frequency:
Annually
By:
Qualified Service Technician
Tools needed:
Protective gloves, drop cloth and a stable
work surface.
• Inspect gasket seal and its condition.
• Inspect fixed glass assembly for scratches and nicks that
can lead to breakage when exposed to heat.
• Confirm there is no damage to glass or glass frame.
Replace as necessary.
• Verify that fixed glass assembly is properly retained and
attachment components are intact and not damaged.
Replace as necessary.
C. Maintenance Tasks - Qualified Service
Technician
The
following tasks must be performed by a qualified ser
-
vice technician.
Glass Cleaning
(Exterior and Interior of Installed Glass)
Frequency:
Seasonally
By:
Qualified Service Technician
Tools Needed
: Protective gloves, ceramic glass cleaner,
drop cloth and a stable work surface.
WARNING!
Risk of Injury!
Glass installation and re
-
moval must be performed only by a qualified service tech-
nician.