C. Mantel and Wall Projections
WARNING! Risk of Fire!
Comply with all minimum clear-
ances as specified. Framing closer than the minimums list
-
ed must be constructed entirely of non-combustible materi-
als (i.e., steel studs, concrete board, etc.).
Note:
Measurement is taken from top of the
opening, NOT the top of the fireplace.
Figure 10.3 Clearances To Combustibles Mantels Or Other
Combustibles Above Appliance
Combustible Mantels
Non-combustible Mantels
Figure 10.4 Clearances To Non-Combustible Mantels Or Other
Non-Combustibles Above Appliance
1/2 IN.
THICK WALL
SHEATHING
12 IN. MAX.
14 IN. MIN. BOTTOM OF MANTEL
TO TOP OF APPLIANCE OPENING
COMBUSTIBLE MANTEL
APPLIANCE OPENING
12 IN.MAX.
1/2 IN.
THICK WALL
SHEATHING
14 IN. MIN. BOTTOM OF MANTEL
TO TOP OF APPLIANCE OPENING
NON-COMBUSTIBLE
MANTEL
6 IN. MAX.
NON-
COMBUSTIBLE
MANTEL
APPLIANCE OPENING