Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K
• 10/18
54
WARNING! Risk of Fire!
Maintain specified air space
clearances to combustibles.
Failure to comply with
these instructions may cause a fire or cause the appli
-
ance to overheat.
CAUTION! Risk of Glass Damage and Cuts!
DO NOT
drill or install any type of screw or fastener into the lower
cover panel. Sharp screw or fastener tips may penetrate
and break the glass or cause cuts.
Note: It is acceptable to use a silicone sealant with
a minimum of 300 ºF continuous exposure rating to
adhere drywall to lower cover panel.
The final fireplace installation can be accomplished by
either the Overlap Fit or Inside Fit method. Reference
Section 10.D regarding installation details associated
with the Inside Fit and Overlap Fit methods.
It is acceptable to pre-drill holes and use self-tapped
screws in the factory-installed non-combustible board to
attach non-combustible backer board for tile, marble, etc.
Refer to Figure 10.2 for acceptable screw location and
screw length requirements.
Self-tapping screws up to one inch long can be installed
through the nailing tab and outer 3 inch edges of the
factory-installed non-combustible board to secure the
drywall adjacent to the factory-installed non-combustible
board. See Figure 10.2.
Do not drill or install screws which may penetrate the
lower cover panel as this will restrict required access
to the glass, battery-back-up, and control module. See
Figure 10.2.
Note:
If the desired look is painted drywall, it is
recommended that no additional screws are installed into
the factory-provided non-combustible board. Only install
the screws provided into the pilot holes located in the
factory-provided non-combustible board.
Figure 10.2 Finishing Details - JADE42IN/JADE42IL and JADE32IN
FACTORY-INSTALLED
NON-COMBUSTIBLE BOARD
LOWER COVER PANEL
= NO SCREWS ALLOWED
= 1 INCH. MAX. SELF-TAPPING SCREWS ALLOWED
= 5 INCH - 7 INCH SELF-TAPPING SCREWS ALLOWED
PILOT HOLES (11 LOCATIONS) TO ATTACH
NON-COMBUSTIBLE BOARD TO FRAMING
WARNING! Risk of Fire!
Maintain specified air space
clearances to combustibles. Inadequate air space could
cause overheating and fire.