15
Majestic • JADE32IN-B, JADE42IN-B, JADE42IL-B Installation Manual • 2619-986 Rev. B • 10/19
C
A
B
Figure 3.7 Passive Heat Front Discharge Framing Dimensions With and Without a Trim Kit
FRONT DISCHARGE MINIMUM FRAMING DIMENSIONS
A
B
C
TRIM KIT*
INSTALLED
(PHTRIM-LINEAR)
NO TRIM KIT**
Required Height of
Discharge Opening
Height of
Discharge
Opening
Clearance to
Discharge
Opening
Width of
Discharge
Opening
JADE32IN-B
Inches
3-1/2
2
48
31-1/8
millimeters
89
51
1219
791
JADE42IN-B
JADE42IL-B
Inches
3-1/2
2
48
48-1/2
millimeters
89
51
1219
1232
* Measurement for Trim Kit = 3-1/2 in. + Additional Finishing Material Thickness
** Measurement without Trim Kit = 2 in. + Additional Finishing Material Thickness. If discharge opening is greater than
3 inches a mesh screen is required.
Framing Dimensions- Passive Heat Font Discharge (PH-FRT-LINEAR)
WARNING! Risk of Fire!
Mesh screen required on bottom of discharge opening (Dimension A)
when discharge opening is greater than 3 inches. Secure mesh to top of framing.
Front Discharge: Air conveyed into the room through one front discharge slot.