22
73D4126
DVKST Series Gas Fireplace
FP1909a
signature command valve
alternate view
8/08
1. Check gas type. The gas supply must be the same as
stated on the appliance’s rating decal. If the gas supply
is different from the fireplace,
STop!
Do not install the
appliance. Contact your dealer immediately.
2. To ease installation, a 24" (610 mm) flex line with manual
shut-off valve has been provided with on this appliance.
Install and attach 1/2" gas line onto shut-off valve.
3. After completing gas line connection, purge air from
gas line and test all gas joints from the gas meter to the
fireplace for leaks. Use a solution of 50/50 water and
soap solution or a gas sniffer.
4. To check gas pressures at valve, turn captured screw
counter clockwise 2 or 3 turns and then place tubing to
pressure gauge over test point. Turn unit to high.
Fig-
ure 25
After taking pressure reading, be sure and turn
captured screw clockwise firmly to reseal. Do not over
torque. Check test points for gas leaks.
Figure 25 -
Signature Command Valve
Pilot Adjustment
Screw
Pressure Outlet
w
arn
In
G
Do not use open flame to check for gas
leaks.
elecTrIcal wIrInG
This fireplace burner system will work without any electrical supply during power outages (battery
back-up system). Electricity is only needed to operate blower, lights and rear burn shut off.
NOTE: If installed in mobile home, fireplace must be bolted securely to floor.
w
arn
In
G
electrical connections should only
be performed by a qualified, licensed
electrician. Main power must be off when
connecting to main electrical power supply
or performing service. all wiring shall be
in compliance with all local, city and state
codes. The appliance, when installed, must
be electrically grounded in accordance
with local codes or in the absence of local
codes, with the national electrical code
anSI/nFpa 70 (latest edition) and canadian
electrical code, cSa c22.1.
cau
TI
on
label all wires before disconnecting when
servicing controls. wiring errors can cause
improper and dangerous operation.
Verify proper operation after servicing.
FP1909a
Pressure Inlet
SIGnaTure coMManD - checK GaS preSSure and elecTrIcal InSTallaTIon
Содержание 500DVKST
Страница 48: ...48 73D4126 DVKST Series Gas Fireplace...
Страница 49: ...73D4126 49 DVKST Series Gas Fireplace...