DVKST Series Gas Fireplace

VenTInG InSTallaTIon 

2.  Assemble the desired lengths of pipe and elbows nec-

essary to reach from the burner system flue up through 
the firestop. Be sure pipe and elbow connections are 
fully twist-locked. 

3.  Cut a hole in the roof using the locating hole as a center 

point.  (Cover  any  exposed  open  vent  pipes  before 
cutting hole in roof). The 10

Z\x

"x10

Z\x

" (241 x 241 mm) 

hole must be measured on the horizontal. Actual length 
may be larger depending on the pitch of the roof. There 
must be a 1" minimum clearance from the vent pipe to 
combustible materials. (Insulation should be considered 
a combustible material).

4.  Connect a section of pipe and extend up through the 

hole.

noTe:

 If an offset is needed to avoid obstructions, you 

must support the vent pipe every three (3) feet. Use wall 
straps  for  this  purpose. 

Page  17,  Figure  17.

  Whenever 

possible, use 45° elbows instead  of 90° elbows. The 45° 
elbow offers less restriction to the flow of the flue gases 
and intake air.
5.  Place the flashing over the pipe section(s) extending 

through  the  roof.  Secure  the  base  of  the  flashing  to 
the roof and framing with roofing nails. Be sure roofing 
material overlaps the top edge of the flashing. There 
must be a 1" clearance from the vent pipe to combustible 
materials.  

6.  Continue to add pipe sections until the height of the vent 

cap meets the minimum building code requirements as 
shown in 

Figure 22

.

noTe:

  You  must  increase  vent  height  for  steep  roof 

pitches. Nearby trees, adjoining roof lines, steep pitched 
roofs, and other similar factors may cause poor draft or 
down-drafting  in  high  winds.  Increasing  the  vent  height 
may solve this problem.

noTe:

 If the vent pipe passes through any occupied areas 

above the first floor, including storage spaces and closets, 
you must enclose pipe. You may frame and sheetrock the 
enclosure with standard construction material. Make sure 
to meet the minimum allowable clearances to combustibles. 
Do  not  fill  any  of  the  required  clearance  spaces  with 
insulation.

  

2 ft. 

Min.

2 ft. Min.

X

12

H*

FP1971

Min chimney clearance

Horizontal Overhang

Termination 
Vent

Lowest 
Discharge 
Opening

Storm Collar

Flashing

Concentric 
Vent Pipe

1" Minimum 
Clearances to 
Combustibles

Vertical Wall

FP1971

Figure 22 - 
Minimum Chimney Clearance

 

roof pitch 

h (feet)

 

Flat to 6/12 

1.0

  Over 6/12 to 7/12 

1.25

  Over 7/12 to 8/12 

1.5

  Over 8/12 to 9/12 

2.0

  Over 9/12 to 10/12 

2.5

  Over 10/12 to 11/12 

3.25

  Over 11/12 to 12/12 

4.0

*H - Minimum height from roof to 
lowest discharge opening of vent

Содержание 500DVKST

Страница 1: ...y or the gas supplier This appliance may be installed in an aftermarket permanently located manufactured home USA only or mobile home where not prohibited by local codes This appliance is only for use...

Страница 2: ...ation 22 Electrical Wiring 22 Command Center Wall Installation 23 Optional Fan Blower Systems 24 Operating Instructions Signature Command 25 Operating Instructions 26 To Turn Off Gas 26 Signature Comm...

Страница 3: ...ace is a vented product This fireplace must be properly installed by a qualified service person The glass door must be properly seated and sealed If this unit is not properly installed by a qualified...

Страница 4: ...side of the dwelling through the vent pipe These appliances have been tested by CSA and found to comply with the established standards for DIRECT VENT GAS FIREPLACE HEATERS in the USA and Canada as fo...

Страница 5: ...s are shown in BTU per hour and are certified without deration for elevations up to 4 500 feet 1 370 m above sea level For elevations above 4 500 feet 1 370 m in USA installations must be in accordanc...

Страница 6: ...mm 39 6 1007 mm 44 6M 1137 mm 456M 108 mm 4456O 1130 mm 38 6 981 mm 23 584 mm 24 610 mm 4956O 1257 mm 30 762 mm 25 635 mm 1156O 292 mm 734126 DVKST KSTDV DIMS Figure 2 Fireplace and Framing Dimensions...

Страница 7: ...x with insulation or other materials This could cause a fire COLD CLIMATE INSULATION If you live in a cold climate seal all cracks around your appliance and wherever cold air could enter the room with...

Страница 8: ...where gasoline or other flammable liquids may be stored Vent pipe routing See Venting section found in this manual for allowable venting configura tions These units can be installed in a bedroom See...

Страница 9: ...CLEARANCES NOTE The combustible area above the facing must not protrude more than 1 2 from the facing If it does it is considered a mantel and must meet the mantel requirements listed in this manual...

Страница 10: ...nal fan must be done prior to final finishing to avoid costly reconstruction Only noncombustible materials i e brick tile slate steel or other materials with a UL fire rating of Zero may be used to co...

Страница 11: ...des and bottom until the flue penetrates the outside wall A minimum 1 clearance all around the flue is acceptable at this point of penetration Vertical sections of this vent system require a minimum o...

Страница 12: ...xposed pipe on the exterior of the house See Installing Vent System in a Chase below If pipe is enclosed in chase it is not exposed It is very important that the venting system maintain its balance be...

Страница 13: ...tion air inlet to any BTU h 3kW 12 30 cm for 10 000 BTU h 3kW 9 other appliances appliances 10 000 BTU h 3kW and 23 cm for appliances 10 000 100 000 Btuh 30kW 36 91 cm BTU h 3kW and 50 000 BTU h for a...

Страница 14: ...f the vent system 1 Determine the height of the center of the horizontal vent pipe exiting through the outer wall Using this dimen sion on the Sidewall Vent Graph below locate the point intersecting w...

Страница 15: ...90 elbows per side wall installation is three 3 Figure 10 Aminimum of 24 is required before a 90 elbow If a 90 elbow is fitted directly after 24 vertical section mounted to the top of the fireplace t...

Страница 16: ...The maximum horizontal run with the 24 vertical pipe is 36 This measurement is taken from the collar of the fireplace or transition elbow to the face of the exterior wall See the Sidewall Venting Gra...

Страница 17: ...he flue and 1 clearance at the sides and bottom until the flue penetrates the outside wall A minimum 1 clearance all around the flue is acceptable at this point of penetration Vertical sections of thi...

Страница 18: ...tion FP1969 offset w wallstrap Figure 19 Offset with Wall Strap and 45 Elbows Roof Flashing Wall Strap 45 Elbows Ceiling Firestop FP1669 within the parameters shown in Figures 20 and 21 2 Set fireplac...

Страница 19: ...roofing material overlaps the top edge of the flashing There must be a 1 clearance from the vent pipe to combustible materials 6 Continue to add pipe sections until the height of the vent cap meets th...

Страница 20: ...l codes not provided A CSA design certified equipment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the CSA design certified equipment shutoff valve fro...

Страница 21: ...end that you install a sediment trap drip leg in supply line as shown in Figure 24 Locate sediment trap drip leg where it is within reach for cleaning Install in piping system between fuel supply and...

Страница 22: ...for gas leaks Figure 25 Signature Command Valve Pilot Adjustment Screw Pressure Outlet WARNING Do not use open flame to check for gas leaks Electrical Wiring This fireplace burner system will work wi...

Страница 23: ...all Do not extend beyond the 15 ft wire cable provided Route the wire from junction box to lower control area at bottom of fireplace Unplug the 12 cable from control box and command center Plug the 15...

Страница 24: ...t side of the outside firebox wall Junction box was installed at the factory 3 The junction box cover has a factory installed romex style strain relief connector After connecting the wires route the w...

Страница 25: ...hone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your finger to push in the master switch Never use tools If the switch will not fu...

Страница 26: ...f you do not smell gas go to next step 4 Install four 4 AA batteries provided in your Homeowner s Manual bag into the command center box Make sure the batteries orientation match 5 Press the master sw...

Страница 27: ...RFSC Three Flame Height Settings X Low battery Indication for Transmitter X Child Proof Lock out X LCD Backlight X Security Codes X Thermostatic Control Mode X Three Brightness Settings for Lights X...

Страница 28: ...epress button One beep for RF receiver ON or two beeps for RF receiver OFF will be given as confirmation 2 After the RF receiver is on holding the OFF button on the Command Center while turning on the...

Страница 29: ...Flip the master switch to the off O position 2 Press the OFF button to Medium Low then Off 3 Hold the OFF button anytime for three seconds This command of OFF will remember all last settings before t...

Страница 30: ...no key is pressed The transmitter will send an OFF signal after reset 4 After reset the transmitter is operating in manual mode The room temperature is shown Manual Mode Figure 32 1 Press the ON butt...

Страница 31: ...f the fireplace is on the blower speed will take effect right away if the fire place is off the receiver will remember this setting and blower is still off 4 If you continue to press FAN button to the...

Страница 32: ...operation Turn the unit OFF before replacing batter ies F FP2150 low battery display 12 08 FP2150 Figure 39 Low Battery Display Child Proof Protection Figure 40 1 Press and hold the ON and OFF buttons...

Страница 33: ...the transfer of oil from hands will reduce the lifespan of the bulbs It is advisable to handle the light bulbs with a clean cloth 4 The light lenses are included in the Homeowner s Manual packet Remov...

Страница 34: ...nly on the carry over areas between the flames To better enable the gas to permeate the rock wool apply the rock wool in light fluffy pieces WARNING Do not use the entire bag of rock wool to cover the...

Страница 35: ...ith the wide end of the log toward you and the flat edge on the bottom right place the log over the right end of all three burners making sure to align the notches in the log with the first tine from...

Страница 36: ...he log should rest against log 3 Log 4 LG729 5 Move to the other side of the unit to place the remaining logs LG730 KSTDV log 5 Log 5 LG730 6 From the front of the unit with the controls on your right...

Страница 37: ...creating a V shape with log 5 LG731 KSTDV log 6 Log 6 LG731 LG732 Log 8 Log 7 LG732 8 Hold log 7 with the Y pointing away from you and place the log on the notch located on the top of log 3 angling t...

Страница 38: ...the control compartment logs and burner areas surrounding the logs clean by vacuuming or brushing at least twice a year Make sure the burner porting pilot air opening and burner air opening are free...

Страница 39: ...ls may be used Handle glass door with care to avoid striking or scratching it on hard objects To clean glass door follow Glass Removal procedure outlined in the Final Installation section Film deposit...

Страница 40: ...h Battery polarity wrong LED on the Command Center does not show solid green The 5 pin connector on the AC board broken or bent AC plug is plugged to AC mains Battery voltage low Using battery Check v...

Страница 41: ...scription Qty 500DVKST 1 Bulb 2 73D0020 2 Bulb Socket 2 73D4521 3 Glass Frame Assembly 2 73D0159 4 Junction Box Assembly not shown 1 26D2128 5 Light Lens 2 73D0022 6 Access Doors 4 73D3258 7 Front Cov...

Страница 42: ...42 73D4126 DVKST Series Gas Fireplace REPLACEMENT PARTS SIGNATURE COMMAND SYSTEM 730024 KHLDV SG parts 12 08 2 22 29 30 17 13 17 12 13 18 16 15 3 1 5 14 11 4 23 24 25 26 26 27 27 28...

Страница 43: ...1 1 73D4528 73D4528 16 Burner Assy Front 2 1 73D4529 73D4529 17 Venturi Front Burner 2 73D4537 73D4537 18 Venturi Middle Burner 1 73D4537 69D1026 19 Wire Valve Control not shown 1 80D0010 80D0010 20...

Страница 44: ...ireplace REPLACEMENT PARTS Item Description Qty 500DVKST 1 Log 1 1 73D4090 2 Log 2 1 73D4091 3 Log 3 1 73D4092 4 Log 4 1 73D4093 5 Log 5 1 73D4094 6 Log 6 1 73D4095 7 Log 7 1 73D4096 8 Log 8 1 73D4097...

Страница 45: ...Front Left Cottage Red 2 73D4135 5 Brick Front Right Cottage Red 2 73D4136 1 Brick Wall Eng Side Tavern Brown 1 73D4149 2 Brick Wall Air Side Tavern Brown 1 73D4150 3 Brick Floor Tavern Brown 2 73D41...

Страница 46: ...46 73D4126 DVKST Series Gas Fireplace HOT 1 2 3 4 5 6 9 7 8 10 730024 KHLDV vent parts VENT components REPLACEMENT PARTS...

Страница 47: ...Heat Deflector Firestop 90 Elbow and Adjustable Pipe 11 to 14 24 Section of Pipe 2 1 Vertical Termination see below see below 5DT VC 2 1 Extended Vertical Termination 58DVA VCE 1283 2 1 High Wind Ver...

Страница 48: ...48 73D4126 DVKST Series Gas Fireplace...

Страница 49: ...73D4126 49 DVKST Series Gas Fireplace...

Страница 50: ...cordance with the above provisions shall comply with NFPA 720 and ANSI UL 2034 listed and IAS certified Signage A metal or plastic identification plate shall be permanently mounted to the exterior of...

Страница 51: ...fetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assembly d...

Страница 52: ...DVKST Series Gas Fireplace MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com Efficiency Ratings Model EnerGuide Ratings D O E Fireplace Efficiency AFUE 500DVKSTNTSC 77 30 67 40 500DVKSTPTSC 7...

Отзывы: