INSTALLATION
INSeRT PLACeMeNT
•
The insert must be placed within a code-conforming
masonry fireplace or a tested and listed zero-clear-
ance (UL-127, solid fuel) fireplace. Repair any fireplace
damage prior to installation.
•
Because the insert uses a circulation blower, clean the
fireplace, smoke shelf and chimney before installing.
•
This heater may be placed in a bedroom. Please be
aware of the large amount of heat this appliance pro-
duces when determining a location.
Figure 5 -
Minimum Openings
fp2994
FIREBOX DIMS
24
6M
”
(629 mm)
22
6M
”
(578 mm)
16
6M
”
(426 mm)
*33
56
”
(841 mm)
*29
N\m
" (759 mm) with
control box and bracket
removed.
ReMOVe COMMAND CeNTeR BRACKeT
In order to fit insert into a smaller opening, the command
center bracket may be removed. Refer to Pages 6 and 9
for dimensions.
If the bracket is removed, the small 2" deep, three-sided
surround, model ICF40S3B is required to mount command
center. Refer to surround instructions.
1. Remove command center from bracket by sliding out
to the right.
Figure 6
2. Carefully lay unit on its back. Remove two (2) screws
holding bracket to insert.
Figure 7
Fp2976
SCS Bracket
Command
Center
Command Center Bracket
FP2976
Figure 6
FP2980
remove bracket screws
Command
Center Bracket
Remove
Screws
Bottom of
Unit
FP2980
Figure 7