VeNTING INSTALLATION 

INSTALLATION PReCAuTIONS

Consult local building codes before beginning the installa-

tion. The installer must make sure to select the proper vent 

system for installation. Before installing vent kit, the installer 

must read this insert manual and vent kit instructions.
Only a qualified installer/service person should install vent-

ing system. The installer must follow these safety rules:

  Wear gloves and safety glasses for protection.

  Use extreme caution when using ladders or when 

on rooftops.

  Be aware of electrical wiring locations in walls and 

ceiling.

The following actions will void the warranty on your vent-

ing system:

  Installation of any damaged venting component.

  Unauthorized modification of the venting system.

  Installation of any component part not manufactured 

or approved by Vermont Castings Group.

  Installation  other  than  permitted  by  these  instruc-

tions.

Read  all  instructions  completely  and 

thoroughly  before  attempting  installation. 

Failure to do so could result in serious injury, 

property damage or loss of life. Operation of 

improperly installed and maintained venting 

system  could  result  in  serious  injury, 

property damage or loss of life. 

W

ARNING

 

NOTIC

e

Failure to follow these instructions will void 

the warranty.

This insert must be vented to the outside. 

The  venting  system  must  NeVeR  be 

attached to a chimney serving a separate 

solid  fuel  burning  appliance.  each  gas 

appliance must use a separate vent system. 

Do not use common vent systems. 

W

ARNING

VeNTING RequIReMeNTS

   The exhaust vent must reline the entire length of chim-

ney and terminate above chimney top.

   Vent must meet all vent manufacturer's requirements 

when installed.

   Make  sure  you  have  the  following  before  installing 

unit:

  3" and 3" UL 1777 Listed gas liner for air inlet and 

exhaust.

  Vertical Terminations kits: HEDV32T812, 

HEDV32T1212

Figure 9 -

Venting Unit

FP2947
vent requirements

Maximum Height 40' 

(12.9 m)

Minimum Height 10' 

(3 m)

Exhaust

Inlet

FP2947

• 

Make  sure  the  exhaust  pipe  on  heater 

connects to exhaust portion of cap. At-

tach flex liners. 

Figure 9

• 

Do not crimp or rupture liner when bend-

ing it into chimney offsets.

W

ARNING

Содержание 40ICFDVLNTSC

Страница 1: ...l For assistance or additional information consult a qualified installer service agency or the gas supplier This appliance may be installed in an aftermarket permanently located manufactured home USA...

Страница 2: ...Gas Shutoff Tool 18 Electrical Installation 19 Electrical Wiring 19 Log Placement 20 Decorative Glass Stone Installation 23 Surround Installation 24 Operating Instructions 26 For Your Safety Read Befo...

Страница 3: ...lled by a qualified service person The glass door must be properly seated and sealed If this unit is not properly installed by a qualified service person with glass door properly seated and sealed com...

Страница 4: ...andards for DIRECT VENT GAS FIREPLACE HEATERS in the USA and Canada as follows LISTED VENTED GAS FIREPLACE HEATER TESTED TO ANSI Z21 88 2009 CSA 2 33 2009 STANDARDS A manufactured home USA only or mob...

Страница 5: ...fied without deration for elevations up to 4 500 feet 1 370 m above sea level For elevations above 4 500 feet 1 370 m in USA installation must be in accordance with the current ANSI Z223 1 NFPA 54 and...

Страница 6: ...ace Insert 24 6QE 621 mm 1356M 337 mm 1256O 318 mm 2 6QE 56 mm 55 6QE 144 mm 1856 460 mm 26 6QE 668 mm 2956 740 mm 256M 57 mm 2356QE 586 mm 4734 40ICFDV insert dims insert dimensions Figure 2 40ICFDV...

Страница 7: ...clearances are subject to local building codes INSERT APPLICATIONS Before installing the gas fireplace insert consider the functioning needs of the fireplace Confirm the size of the fireplace cavity t...

Страница 8: ...is considered a mantel and must meet the mantel requirements listed in this manual HEARTH REQUIREMENTS The insert must be installed on a noncombustible hearth extending a minimum of 10 254 mm from th...

Страница 9: ...IMS 24 6M 629 mm 22 6M 578 mm 16 6M 426 mm 3356 841 mm 29N m 759 mm with control box and bracket removed REMOVE COMMAND CENTER BRACKET In order to fit insert into a smaller opening the command center...

Страница 10: ...ventilated OPEN ALL WINDOWS DURING INITIAL BURN OFF CURING PHASE Burn your insert for at least six 6 hours on HIGH the first time you use it Place the fan in the OFF position during this time Fp1921...

Страница 11: ...ttempting installation Failure to do so could result in serious injury property damage or loss of life Operation of improperly installed and maintained venting system could result in serious injury pr...

Страница 12: ...resize orifice for use at high altitude contact your dealer High Temp Silicone FP2948 exhaust pipe 3 and 3 UL 1777 Gas Liner Apply high temperature silicone to lines on both ends and secure with two 2...

Страница 13: ...ecommended block off plate noncombustible metal Prevents odors from chimney entering room UL 127 Solid Fuel Z C Fire box Figure 11 Inlet and Exhaust Reline NOTE You may use a reline configuration with...

Страница 14: ...es 4 Pull glass frame away from unit and lift up and away WARNING HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS AVERTISSEMENT Un panneau vitr chaud peu...

Страница 15: ...Brick Retainer Bracket Lower Brick Retainer Bracket Front Brick Retainer Right Brick Panel Left Brick Panel FP2985 Figure 13 Install Brick Panels IMPORTANT The fireplace must have an approved brick ki...

Страница 16: ...vided ACSAdesign certified equipment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connec tion Purchase the CSA design certified equipment shutoff valve from your dealer Fo...

Страница 17: ...aminants This keeps them from going into the burner system gas con trols If sediment trap drip leg is not installed or is installed wrong burner system may not run properly NOTE The gas line connectio...

Страница 18: ...and soap solution or a gas sniffer 4 To check gas pressures at valve turn captured screw counter clockwise 2 or 3 turns and then place tubing to pressure gauge over test point Turn unit to high Figure...

Страница 19: ...rical supply Electricity is only needed to operate blower Verify proper operation after servicing Electrical connections should only be performed by a qualified licensed electrician Main power must be...

Страница 20: ...e heater Only use the logs supplied with the unit Failure to position the parts in accordance with diagrams below or to use only parts specifically approved for this heater may re sult in property dam...

Страница 21: ...e 23 Log 3 LG1143 Figure 24 Log 4 LG1144 Figure 25 4 Place log 2 on the two 2 pins provided on the right front of the front burner The protrusion on the bottom of the log should rest between the front...

Страница 22: ...26 8 Place log 6 on top of the key provided on top of log 2 Rest the narrow end toward the right side brick and log 1 Figure 26 9 Place log 7 on top of the keys provided on top of logs 1 and 2 Figure...

Страница 23: ...corative glass provided in the kit as desired Lay glass on top of burner and cover burner area with one 1 layer Glass may be used around the perimeter next to the wall Make sure glass is not blocking...

Страница 24: ...assembly Page 14 Figure 12 2 Align surround holes with insert and attach with screws provided 3 Re attach glass door assembly Figure 31 Medium Surround with Front Control Access Figure 32 Small Surro...

Страница 25: ...34 40ICFDV Gas Fireplace Insert 25 surround installation FP2953 sm surr 3 side ctrl Figure 33 Small Surround with Side Control Access FP2953 FP2954 contemporary surround Figure 34 Trimmable Surround F...

Страница 26: ...ollow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your finger to push in the master switch Never use tools If the switch will not func tio...

Страница 27: ...to next step 4 Press the master switch to the ON position Within eight 8 seconds it will beep once This indicates the system is ready 5 Press ON button Sparker will spark and pilot flame will light 6...

Страница 28: ...els 2 Remove log support bracket by removing two 2 screws in rear and one 1 screw on each side wall FP1940 air shutter part open Air Shutter FP1940 Figure 35 Push Adjustment Lip Up to Open Air Shutter...

Страница 29: ...battery Indication for Transmitter X Child Proof Lock out X LCD Backlight X Security Codes 16 X Countdown 6 hr Timer X Standard Thermostatic Control Mode X Smart Mode Thermostat Auto Flame Blower Modu...

Страница 30: ...Push the RF receiver On Off button on the control board RF OFF On Off Beep once for ON and beep twice for OFF Learn Remote Hold the OFF button while turning on the master switch Transmitter Beep twic...

Страница 31: ...ing GREEN Flashes every 1 sec for 10 sec AC Power On GREEN solid Pressure Switch Failed Power Vent only One RED every 2 sec until manual reset Self Diagnostics Chart The Command Center has a self diag...

Страница 32: ...ws The blue LED backlight lights up for 8 seconds when any of the touch buttons is pressed The menus include TIMER THERMO LIGHT FAN and AUX Rear Burner Control The adjustment arrows include ON up and...

Страница 33: ...for 10 seconds 4 During the 10 sec onds press the OFF button on the transmitter to learn Another two beeps will be given to confirm a success ful learning Figure 42 TOUCH SCREEN REMOTE CONTROL OPERAT...

Страница 34: ...completely when the timer counts down to zero 6 To exit Timer Mode a Push and hold the TIMER button for 3 seconds Or b Use the OFF down buttons to decrease the Set Time to zero Or c Slide down on the...

Страница 35: ...down button to increase de crease the blower speed 3 Press the fan button again to confirm the speed set ting If the fireplace is on the blower speed will take effect right away if the fireplace is o...

Страница 36: ...A touch any place in the touch area to bring up the icons then press TIMER but ton and THERMO button at the same time for 3 sec onds The backlight will flash once to indicate that the setting has chan...

Страница 37: ...is blank 2 Check battery installation or replace batteries 3 LCD display shows funny display 3 Reset the transmitter see Resetting the Transmitter section 4 Appliance does not come on 2 The transmitte...

Страница 38: ...nd lint to the surface of the glass The initial paint curing of the appliance can also leave a slight film on the glass This is a temporary problem CLEANING and MAINTENANCE Figure 52 Typical Burner Fl...

Страница 39: ...ain burner and pilot 5 Carefully replace log set and embers in their correct positions Refer to Pages 20 through 23 6 Replace door 7 Relight pilot Refer to Page 26 8 Turn on main burners Allow logs to...

Страница 40: ...e adjusted Contact dealer where you bought heater 4 Remove rock wool Clean burner and burner ports Figure 59 Figure 54 Before taking unit apart check pilot flame Flame should touch thermo couple and t...

Страница 41: ...gh Battery polarity wrong LED on the Command Center does not show solid green The 5 pin connector on the AC board broken or bent AC plug is plugged to AC mains Battery voltage low Using battery Check...

Страница 42: ...42 20304734 40ICFDV Gas Fireplace Insert REPLACEMENT PARTS 34a b 6 1 2 3 4 5 8 22 23 25 27 51 43 46 48 4734 40ICFDV parts 21 28 37 35 36 41 40 39 7 19 24 26 29 30 32 33 22 42 45 20 21 18 31 9 44 47 50...

Страница 43: ...6 Venturi Rear 1 20304031 20304032 27 Gasket Venturi 1 45D0032 45D0032 45D0032 28 Pilot Assembly 1 80D0039 80D0040 80D0006 29 Shutoff Valve 1 27D0303 27D0303 27D0303 30 Union 1 27D7026 27D7026 31 Elbo...

Страница 44: ...4729 20304729 49 Blower 2 56D2196 56D2196 56D2196 50 Glass Latch Tool 1 20303972 20303972 20303972 51 Blower Wire Assy not shown 2 41D0203 41D0203 41D0203 52 Flex Line not shown 1 20303981 20303981 20...

Страница 45: ...ular Double Door Satin Black ICF40R2DSB 6b Rectangular Double Door Vintage Iron ICF40R2DVI 6c Rectangular Double Door Textured Mocha ICF40R2DTM 6d Rectangular Double Door Brushed Nickel 40ICFR2DBN 6e...

Страница 46: ...y with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed Massachusetts Residents Only Please re...

Страница 47: ...10 year warranty will be void if the appliance is not installed by a qualified installer in accor dance with the installation instructions The limited 10 year warranty will also be void if the applian...

Страница 48: ...nt nerg tique de foyer au gaz nerguide Selon CSA P 4 1 09 Efficiency Ratings Model EnerGuide Ratings D O E Fireplace Efficiency AFUE 40ICFDVLNTSC 75 9 70 67 40ICFDVLPTSC 78 7 71 21 40ICFDVCNTSC 77 3 6...

Отзывы: